Tecumseh AE2430Z‑FZ3C 1hp Refrigerator compressor
Tecumseh AE2430Z-FZ3C R404A Reciprocating Compressor: 14.51 cm3, Four Suffixes, and a Horsepower the Record Never Prints
The string, character by character
Five segments carry the model, and each one can be read against a field the manufacturer's data sheet prints.
| Segment | What the record shows | Which field proves it |
|---|---|---|
| AE | The series | Version reads AE Series |
| 2 | The low back pressure family | Application reads LBP - Low Back Pressure, evaporating range minus 40 C to minus 10 C |
| 30 | The duty index, near 3,000 BTU/h | The AE2410, AE2420 and AE2430 rows at the same rating point |
| Z | R-404A | Refrigerant reads R-404A |
| FZ3C | The build: supply, market, agency envelope | Four AE2430 variants, one displacement, four supplies |
The first two characters are confirmed by a single field and are the least interesting. The third segment is the one buyers misread, because a four digit number in the middle of a compressor name looks like a displacement and is not one: 30 is not thirty cubic centimetres, is not three and a decimal point, and does not divide by anything to produce 14.51. The fourth segment carries the refrigerant in a single letter, and the record shows at least five such letters in the same family, each with its own pair of refrigerants: Z rows print R-404A, Y rows print R-134a and R-513A, U rows print R-290, A rows print R-401A, and P rows print a four refrigerant blend list. The fifth segment, the part after the hyphen, is where the ordering risk sits, and it gets its own section below.
The application class is worth a sentence of its own, because it sets the physics that everything else follows. Every AE2 row opened for this article prints LBP - Low Back Pressure with an evaporating range of minus 40 C to minus 10 C. The one AE4 row opened prints HBP/CBP - High/Commercial Back Pressure with a range of minus 15 C to plus 15 C. A 2 in that position is therefore not a size, it is a statement that the machine is designed to boil refrigerant at freezer temperatures, and the consequences run through the whole data sheet: the motor is high start torque, the cooling is by fan, and the displacement needed for a given duty is several times the displacement a comfort cooling machine would use for the same number of BTU per hour.
What the manufacturer prints at 14.51 cm3
The model data sheet is a single server rendered page keyed by the full string, and it prints the following fields for AE2430Z-FZ3C. Every value below was read from that page in this round.
| Field | Printed value |
|---|---|
| Model | AE2430Z-FZ3C |
| Compressor type | Reciprocating |
| Application | LBP - Low Back Pressure |
| Refrigerant | R-404A |
| Voltage / frequency | 220-240 V, 50 Hz |
| Version | AE Series |
| Evaporating temperature range | minus 40 C to minus 10 C, that is minus 40 F to 14 F |
| Motor torque | High Start Torque (HST) |
| Compressor cooling | Fan |
| Weight | 12 kg |
| Displacement | 14.51 cm3 |
| Oil type | Polyolester |
| Oil viscosity | 32 cSt |
| Oil charge | 366.3 cm3 |
| Locked rotor amps | 21.5 A |
| Rated load amps, 50 Hz | 3.52 A |
| Voltage range, 50 Hz | 198-253 V |
| Rated load amps, 60 Hz | 0 |
| Maximum continuous current | 0 A |
| Motor resistance, main winding | 3.37 ohm |
| Motor resistance, start winding | 11.99 ohm |
| Motor type | CSR |
| Agency approvals | CE listed, CCC listed, IRAM listed, TIS listed |
Four things in that table are worth more attention than the rest.
The voltage range is wider than the nameplate. The nameplate says 220-240 V; the range field says 198-253 V. A buyer sizing contactors and protection against the nameplate alone will be wrong at both ends, and a buyer who assumes the midpoint of the nameplate will be wrong in a market where the nominal sits at the bottom of the range and the supply sags below it.
Two fields print zero, and they are not measurements. Rated load amps at 60 Hz is 0 and maximum continuous current is 0. This is a 50 Hz build, so the 60 Hz current has no value to print and the page prints a placeholder instead. Reading that zero as "this compressor draws no current at 60 Hz" is the kind of mistake a specification table invites, and the correct reading is that the field does not apply to this build.
The motor is a CSR machine with a high start torque label and a fan. Capacitor start, capacitor run, high start torque: that combination is what a low back pressure compressor needs to start against an already equalised but still heavy crankcase load in a warm condensing unit, and the fan tells you the shell is air cooled in the enclosure rather than suction cooled by the return gas.
The oil charge and viscosity are printed, which is unusual on a summary page and useful in the field. 366.3 cm3 of polyolester at 32 cSt is the charge to restore after a system repair, and the polyolester specification is not optional on an R-404A machine: a mineral oil substitution will destroy the compressor.
The two ASHRAE blocks, and one column that does not close
The data sheet prints two rating blocks, one at 200 V and one at 240 V, both at the same test point: evaporating minus 23 C, condensing 54 C, ambient 32 C, return gas 32 C, liquid 45 C.
| Quantity | Block at 200 V, 50 Hz | Block at 240 V, 50 Hz |
|---|---|---|
| Refrigeration capacity, BTU/h | 2,700 | 2,700 |
| Refrigeration capacity, kcal/h | 680 | 680 |
| Refrigeration capacity, W | 791 | 791 |
| Input power, W | 587 | 631 |
| Efficiency, BTU/Wh | 4.6 | 4.28 |
| Efficiency, kcal/Wh | 1.16 | 1.08 |
| Efficiency, W/W | 1.35 | 1.35 |
Two blocks, seven quantities each, and the columns disagree in exactly one place. Recomputing with 3.412142 BTU per Wh and 3.968321 BTU per kcal:
| Check | Printed | Recomputed | Residual |
|---|---|---|---|
| 2,700 BTU/h in W | 791 | 791.29 | 0.04 per cent |
| 2,700 BTU/h in kcal/h | 680 | 680.39 | 0.06 per cent |
| 200 V: 791 W over 587 W | 1.35 | 1.3475 | 0.2 per cent |
| 240 V: 791 W over 631 W | 1.35 | 1.2536 | 7.7 per cent high |
| 240 V: 2,700 BTU/h over 631 W | 4.28 | 4.279 | nil |
| 240 V: 4.28 BTU/Wh in kcal/Wh | 1.08 | 1.0785 | 0.1 per cent |
| 200 V: 4.6 BTU/Wh in W/W | 1.35 | 1.3481 | 0.1 per cent |
Six checks close to within a rounding step and one does not. The 240 V block's W/W figure of 1.35 is the 200 V figure left in place: its own BTU/Wh column, its own input power and its own kcal/Wh column all agree with each other and with 791 divided by 631, which is 1.25 to two places. The practical reading is not that the machine performs badly at 240 V, it is that the printed efficiency cell for the 240 V test voltage should be 1.25, not 1.35, and that anyone quoting 1.35 W/W for this compressor at 240 V is quoting a transcription.
The other fact that falls out of the two blocks is a real one, not a transcription: the printed capacity is identical at both test voltages, 2,700 BTU/h and 791 W, while the input power rises from 587 W to 631 W. That is 7.5 per cent more electrical input for the same printed cooling at the top of the voltage window. Whether that is a physical property of the winding at 240 V or an artefact of how the table was filled, the record does not say, but the two numbers are there to be read.
Four suffixes, one displacement
Four strings in the manufacturer's index begin with AE2430. They share the base, the family, the application class and the swept volume, and they differ in everything a buyer must physically connect.
| String | Refrigerant | Supply | Displacement | Weight | Locked rotor amps | Rated load amps, 50 Hz | Max continuous current | Printed capacity |
|---|---|---|---|---|---|---|---|---|
| AE2430Z-FZ3C | R-404A | 220-240 V 50 Hz | 14.51 cm3 | 12 kg | 21.5 A | 3.52 A | 0 | 2,700 BTU/h at 200 V and at 240 V |
| AE2430Z-AA3C | R-404A | 115 V 60 Hz | 14.51 cm3 | 11 kg | 48 A | 0 | 0 | 3,000 BTU/h |
| AE2430Z-GS3C | R-404A | 220 V 50 Hz and 220 V 60 Hz | 14.51 cm3 | 12 kg | 22.5 A | 3.32 A | 0 | 2,650 BTU/h at 50 Hz, 3,100 BTU/h at 60 Hz |
| AE2430U-ES3C | R-290 | 220 V 60 Hz | 14.51 cm3 | 11 kg | 27.5 A | 0 | 4.47 A | 2,800 BTU/h |
The displacement column is identical in all four rows, which settles what the suffix is not: it is not a size, and the part after the hyphen never changes the swept volume. What it does change is the refrigerant in one case and the electrical envelope in three. AE2430U-ES3C is not an R-404A machine at all, it is an R-290 build with a different refrigerant letter and a different maximum continuous current, and substituting one for the other on the basis of a shared AE2430 prefix would be a serious error. Within the three R-404A rows, the locked rotor current moves from 21.5 A to 48 A and the weight from 12 kg to 11 kg, which is the difference between a European market build and a North American 115 V market build, and no amount of reading the model string as a size will reveal it.
The first letter of the suffix group also tracks the supply, and the pattern holds across every model opened this round: an A group is 115 V 60 Hz, a D group is 115-127 V 60 Hz, an E group is 220 V 60 Hz, an F group is 220-240 V 50 Hz, and a G group is 220 V 50 Hz with a 220 V 60 Hz variant. The record does not print a legend for these letters, so this is a reading of the supply field on eleven separate pages rather than a quotation of a published key, and it should be checked against the supply field of the exact string being ordered rather than assumed. The AE product family page in the manufacturer's index lists the builds side by side, and it is the fastest way to see how many strings sit behind one base number.
One more thing about ordering the full string: the manufacturer's index also carries an address for AE2430U-ES3D, and that model's data page prints no field values at all, no refrigerant, no voltage, no displacement. An address in an index is not a specification, and the only safe order is the one that returns a page with numbers on it.
The two digits are a duty index, not a swept volume
The AE2 family in the manufacturer's index runs from 10 to 30 in that middle pair, and the record shows what the pair actually controls. The table below prints, for each model opened, the refrigerant letter, the swept volume, and the highest cooling capacity printed on that model's page at the low back pressure point of minus 23 C evaporating and 54 C condensing.
| Model | Refrigerant | Displacement | Capacity at the LBP point | Test voltage |
|---|---|---|---|---|
| AE2410Z-AA1A | R-404A | 5.02 cm3 | 1,050 BTU/h | 115 V 60 Hz |
| AE2410Y-AA1A | R-134a, R-513A | 9.39 cm3 | 1,168 BTU/h | 115 V 60 Hz |
| AE2413Y-AA1B | R-134a, R-513A | 12.01 cm3 | 1,467 BTU/h | 115 V 60 Hz |
| AE2415A-FZ1B | R-401A | 12.48 cm3 | 1,450 BTU/h | 220-240 V 50 Hz |
| AE2415P-FZ1B | R-404A, R-452A, R-454C, R-455A | 7.33 cm3 | 1,300 BTU/h | 220-240 V 50 Hz |
| AE2415Z-GS1B | R-404A | 7.33 cm3 | 759 BTU/h | 220 V 60 Hz, at minus 35 C evaporating |
| AE2420Z-ES1A | R-404A | 9.33 cm3 | 2,050 BTU/h | 220 V 60 Hz |
| AE2420U-AA1A | R-290 | 10.96 cm3 | 2,000 BTU/h | 115 V 60 Hz |
| AE2425Z-FZ3C | R-404A | 12.01 cm3 | 2,250 BTU/h | 220-240 V 50 Hz |
| AE2430Z-FZ3C | R-404A | 14.51 cm3 | 2,700 BTU/h | 200-240 V 50 Hz |
Read down the capacity column and the index behaves like a duty band in hundreds of BTU/h: 10 lands between 950 and 1,168, 13 lands at 1,300 to 1,467, 20 lands at 2,000 to 2,050, 25 lands at 2,250, and 30 lands at 2,700. Read across any single row and the same index does not fix the displacement: at index 10 the R-404A build displaces 5.02 cm3 while the R-134a build displaces 9.39 cm3, and at index 15 the R-404A build displaces 7.33 cm3 while the R-401A build displaces 12.48 cm3. That is not a printing error, it is volumetric capacity: a cubic centimetre of R-134a delivers roughly two thirds of the cooling of a cubic centimetre of R-404A at the same evaporating temperature, so a machine of a given duty needs more swept volume on R-134a than on R-404A. The digits name the duty, and the refrigerant letter decides how much metal it takes to reach it.
The one row that breaks the pattern is AE2415Z-GS1B, at 759 BTU/h against an index of 15. It is also the one row in the table rated at a different evaporating temperature, minus 35 C rather than minus 23 C. A lower evaporating temperature costs capacity at any given displacement, which is exactly why that row is worth printing rather than quietly dropping: the index is a duty band at a stated point, not a constant.
The AE4 rows make the same point from the other direction. AE4430Z-AA1A carries the same 30 index and the same R-404A letter, and it displaces 5.16 cm3 to deliver 3,236 BTU/h, because it is rated in the high and commercial back pressure class with an evaporating range of minus 15 C to plus 15 C. A cubic centimetre does far more work at plus 5 C evaporating than at minus 23 C, by a factor of nearly three here, and this is why the number in the middle of the model string can only be read together with the class digit and the refrigerant letter that sit beside it.
The nearest sibling, and a rating point that moves
The closest machine in the index to AE2430Z-FZ3C is AE2425Z-FZ3C. It shares the series, the low back pressure class, the R-404A charge, the Z letter and the FZ3C build, and it differs only in the middle pair. Setting the two records side by side at their 240 V blocks gives a clean 20 per cent step and one warning.
| Quantity | AE2425Z-FZ3C | AE2430Z-FZ3C | Change |
|---|---|---|---|
| Displacement | 12.01 cm3 | 14.51 cm3 | plus 20.8 per cent |
| Printed capacity | 2,250 BTU/h | 2,700 BTU/h | plus 20.0 per cent |
| Printed capacity in W | 659 W | 791 W | plus 20.0 per cent |
| Input power at 240 V | 479 W | 631 W | plus 31.7 per cent |
| Printed efficiency | 1.38 W/W | 1.35 W/W | minus 2.2 per cent |
| Liquid temperature of the rating | 32 C | 45 C | 13 K warmer |
The capacity step is almost exactly proportional to the displacement step, 20.0 per cent against 20.8 per cent, which is the behaviour a buyer would hope for when moving up one index. The input power step is not proportional, 31.7 per cent against 20.0 per cent, and the printed efficiency barely moves. The warning is in the last row: the two machines are not rated at the same liquid temperature. The smaller one is rated with 32 C liquid entering the expansion device, the larger one with 45 C liquid. A warmer liquid temperature raises the flash gas fraction and therefore the input power at the same evaporating and condensing temperatures, so part of that 31.7 per cent belongs to the rating point rather than to the machine. The honest conclusion is the narrow one: the larger machine returns 20 per cent more printed capacity for 20.8 per cent more displacement, and the two pages cannot settle what it costs in power, because they describe different test points. A buyer comparing these models on the W/W column alone is comparing two different tests.
What the shop prints across its Tecumseh reciprocating line
The shop carries the Tecumseh brand and a deep reciprocating catalogue. What it does not carry is this string. Before turning to that absence, here is what its own pages print for the 24 series and the 24 series neighbours, read in this round from 238 Tecumseh product pages, of which 44 are AE, CAE or RGA reciprocating models. All values in this table are seller printed data, not manufacturer data, and they are shown as such.
| Shop model | Shop label | Displacement | Refrigerant | Oil charge |
|---|---|---|---|---|
| CAE2417Z | 7/16 HP | 11.3 cm3 | R-404A | 350 cm3 |
| CAE2420Z | 1/2 HP | 12.6 cm3 | R-404A | 350 cm3 |
| CAE2424Z | 5/8 HP | 15.1 cm3 | R-404A | 290 cm3 |
| AE2410Y | 1/3 HP | 12.1 cm3 | R-134A | 350 cm3 |
| AE2412Y | 3/8 HP | 14.2 cm3 | R-134A | 350 cm3 |
| CAE2414Y | 7/16 HP | 16 cm3 | R-134A | 350 cm3 |
| CAE2416E | 2/5 HP | 11.2 cm3 | R22 | 350 cm3 |
| CAE2420E | 1/2 HP | 12.5 cm3 | R22 | 350 cm3 |
| RGA/HGA2432Z | 4/5 HP | 11.5 cm3 | R-404A | 290 cm3 |
| RGA/HGA2436Z | 1 HP | 12.7 cm3 | R-404A | 290 cm3 |
| CAJ2432Z | 3/4 HP | 18.3 cm3 | R-404A | 887 cm3 |
| CAJ2440Z | 1 HP | 21 cm3 | R-404A | 887 cm3 |
| CAJ2446Z | 1 HP | 26.2 cm3 | R-404A | 887 cm3 |
| CAJ2464Z | 1 1/2 HP | 34.5 cm3 | R-404A | 887 cm3 |
Two readings follow. The first is coverage: the shop's 24 series runs from 11.2 cm3 to 34.5 cm3, and the machine this article is about, at 14.51 cm3 and R-404A, sits inside that band, between the shop's CAE2420Z at 12.6 cm3 and its CAE2424Z at 15.1 cm3. The second is caution: the displacement column on those pages is seller data and does not follow the manufacturer's index rule, so 24 in a shop slug and 30 in a manufacturer string are not comparable quantities. Anyone matching the two catalogues has to match refrigerants, displacements and supplies, in that order, and treat the digits as names rather than numbers.
The horsepower the record never prints
The request that produced this article called AE2430Z-FZ3C a 1 hp refrigerator compressor. The manufacturer's model record contains no horsepower field at all: it prints an application class, a refrigerant, a supply, a swept volume, an oil charge, electrical values and agency approvals, and it stops there. Horsepower is therefore not a value this article can quote, and the useful question is what the record does say that a horsepower label is standing in for.
What it says is a capacity and a current. 2,700 BTU/h, which is 791 W, at minus 23 C evaporating and 54 C condensing, at 1.35 W/W on the 200 V block. A rated load current of 3.52 A at 220-240 V and a locked rotor current of 21.5 A, a ratio of 6.1 to one, which is what the contactor and the overload have to survive. Those four numbers, not a horsepower figure, are what selects this compressor into a condensing unit.
The shop's own labelling shows why the horsepower figure cannot travel between families. Five rows on those 238 pages carry the 1 HP label: RGA/HGA2436Z at 12.7 cm3, CAJ9510Z at 18.3 cm3, CAJ2440Z at 21 cm3, CAJ2446Z at 26.2 cm3, and CAJ4511Y at 32.7 cm3. That is a span from 12.7 cm3 to 32.7 cm3, a factor of 2.6, on one label, because horsepower on this class of machine is quoted at the family's own reference point and families do not share one. The 12.7 cm3 row and the 21 cm3 row carry the same label. A buyer who sorts a catalogue by horsepower is therefore sorting on a label that is not commensurable across families, and a buyer who sorts on displacement and refrigerant, then checks the rated capacity at the application's evaporating temperature, is doing the comparison the record supports.
For AE2430Z-FZ3C specifically, the label in the request and the record do not contradict each other, they simply do not meet: the record has no field for the label to occupy. If the compressor must be matched to a 1 hp condensing unit, the match has to be made on the unit's rated capacity at the working evaporating temperature and on the compressor's electrical values, both of which the manufacturer prints.
No page on this site prints the string
The absence is measured, not assumed. The shop's sitemap lists 6,150 addresses, and the Tecumseh brand occupies 242 of them. Searching the whole file for the model yields nothing.
| Search | Hits |
|---|---|
| Addresses in the shop sitemap | 6,150 |
Addresses containing tecumseh |
242 |
Tecumseh product pages under /products/ |
238 |
| AE, CAE or RGA reciprocating pages among those | 44 |
Addresses containing ae2430 |
0 |
Addresses containing ae2430z |
0 |
Addresses containing fz3c |
0 |
Addresses containing hc2430 |
0 |
| Candidate URLs probed directly, all four returning 404 | 6 |
The four direct probes used the shop's own naming pattern for this brand, which is tecumseh-reciprocating-compressor- plus the lower case model, with and without the bill of material suffix, in both the lower case and mixed case variants the shop actually uses. All six returned 404, so the zero in the sitemap is confirmed rather than merely observed. What the shop does carry is the Tecumseh brand hub, the rotary sibling, the wider reciprocating compressor category, the 24 series pages listed above, and one long form write up on a low temperature piston model.
The same absence does not hold at the manufacturer, and the contrast is worth stating plainly. Tecumseh's own sitemap carries 16,017 addresses, of which 11,801 are product pages, and seven of them contain ae2430: the four strings in the table above, one condensing unit built on the same base, and two further variants. The manufacturer's own product record for the string is a live page in that catalogue, and it resolves to the same data sheet this article has been reading. Purchasing this compressor means ordering a string the shop's catalogue does not yet print, from a manufacturer whose record documents it in detail. That is a sourcing fact, not a criticism: the category pages above are the right starting point, and the technical data in this article is what a buyer needs in hand before asking.
Pressure, temperature, and what low back pressure asks of a buyer
The evaporating range of minus 40 C to minus 10 C is the design envelope, and it is wide. It covers a frozen food cabinet at the cold end and a chilled display at the warm end, with the manufacturer's own rating point at minus 23 C sitting nearer the cold end. Two consequences follow that the summary table makes easy to miss.
The first is that the printed capacity is a freezer capacity. 2,700 BTU/h at minus 23 C evaporating and 54 C condensing is not the same 2,700 BTU/h that a comfort cooling catalogue would quote, and the two cannot be compared. A machine rated at 2,700 BTU/h with a 45 C liquid temperature and a 32 C ambient is doing heavier work than a machine rated at the same figure on a cooler test point, which is why the rating point has to travel with the number.
The second is that the high start torque label is a requirement, not a feature. Low back pressure compressors start against a crankcase that has been sitting at condensing pressure, and in a warm ambient that start load is the dimensioning case for the contactor, the capacitor and the overload. The 21.5 A locked rotor current is the number that sizes those parts; the 3.52 A running current is the number that sizes the wiring.
The refrigerating side of the envelope also decides the oil. Polyolester at 32 cSt is printed for a reason: R-404A is not miscible with mineral oil, and the 366.3 cm3 charge is the quantity to restore if the system is opened. There is no field on the page that says what happens if a different oil is used, because the answer is that the compressor fails.
Refrigerant choice is also a compliance question rather than only a thermodynamic one. R-404A is an HFC blend, and restrictions on high global warming potential refrigerants are published market by market; the Environmental Protection Agency's hydrofluorocarbon programme is where the United States rules and the allowance data behind them sit. This article prints no GWP figure for R-404A, because no primary source for one could be verified in this round, and a number that cannot be sourced is worse than no number at all. What a buyer should carry away is that the refrigerant in the string is part of the order, not a detail to be settled at the charging station.
What to ask before ordering
Six questions cover the gaps this record leaves open, and each has an answer the manufacturer prints somewhere.
| Question | Why it matters | Where the answer sits |
|---|---|---|
| Which full string, including the suffix? | The four AE2430 builds differ in refrigerant and supply at identical displacement | Model field on the data sheet |
| Which supply, and over what window? | 220-240 V nameplate against a 198-253 V range | Voltage and voltage range fields |
| Which refrigerant, R-404A or R-290? | AE2430U-ES3C is a propane build, not interchangeable | Refrigerant field |
| Which rating point? | The 2,700 BTU/h figure assumes 45 C liquid and 32 C ambient | The ASHRAE block's condition rows |
| Which oil and how much? | Polyolester 32 cSt, 366.3 cm3 | Oil fields |
| Which approvals for the destination market? | CE, CCC, IRAM and TIS are listed for the FZ3C build | Agency approval field |
A seventh question has no answer on the page and is worth asking anyway: whether a 60 Hz build is available on the same base, because AE2430Z-AA3C and AE2430Z-GS3C both exist and both carry the 60 Hz case, at different voltages. The record is a specification, not a stock list, and interchangeability between the builds is the manufacturer's call rather than a reader's inference.
Three documents sit behind those questions without changing a single value in this article. The compressor is a component under IEC 60335-2-34, the assembled refrigerating system it goes into falls under IEC 60335-2-40, and the rating practice that produces a figure such as 2,700 BTU/h at a stated evaporating, condensing, ambient and liquid temperature is set out by AHRI. What those three decide is not the number, it is what an installer is allowed to sign off and what a test house will ask for.
Tecumseh's product bulletins are the next thing to read after the model page. The data sheet gives the values; the bulletins carry the installation and application guidance that tells an installer how much of the envelope can actually be used, and they are worth a look before a string is ordered rather than after it arrives.
What this article rests on
Every figure above was read in this round from the source named beside it. No value has been carried over from another model's page, and no value has been computed from a photograph.
| Source | What it establishes | Status |
|---|---|---|
| Manufacturer model data sheet for AE2430Z-FZ3C | Every field in the specification table, both ASHRAE blocks, all condition rows | Read in full from the rendered page |
| Manufacturer model data sheets for AE2425Z-FZ3C, AE2430Z-AA3C, AE2430Z-GS3C, AE2430U-ES3C, AE2430U-ES3D | The suffix comparison and the liquid temperature difference | Read in full, five pages |
| Manufacturer model data sheets for nine further AE2 and AE4 models | The duty index table | Read in full, nine pages |
| Manufacturer product index | 11,801 product pages, seven containing ae2430, one string with an address but no printed values |
Searched in full |
| The shop's Tecumseh product pages, 238 read | The shop tables, the horsepower spread, the coverage statement | Read in full for the rows quoted |
| The shop's sitemap, 6,150 addresses | The absence measurement and the 404 confirmations | Searched in full |
| The shop's brand hub, category and blog pages | The links in this article and the routing of a buyer to the right family | Probed, all returning 200 |
| IEC 60335-2-34, IEC 60335-2-40, AHRI standards pages | The standards that govern a hermetic motor compressor and its assembled system | Probed, all returning 200 |
| The Environmental Protection Agency's hydrofluorocarbon programme | Where restrictions on high warming potential refrigerants are published for the United States market | Probed, returning 200 |
Three limits are worth stating rather than hiding. The manufacturer prints no horsepower, so any horsepower figure in this article's title is the trade label from the request and not a manufacturer value. The two efficiency columns of the 240 V block do not agree with each other, and this article follows the column that closes. The nearest sibling is rated at a different liquid temperature, so the efficiency comparison between the two is left open rather than settled.
Frequently asked questions
Is AE2430Z-FZ3C a 1 hp compressor?
The manufacturer's record does not state a horsepower. It states 14.51 cm3 of displacement, 2,700 BTU/h at minus 23 C evaporating and 54 C condensing, a rated load current of 3.52 A at 220-240 V and a locked rotor current of 21.5 A. In the shop's own labelling the nearest 1 HP rows are found at 12.7 cm3 and at 21 cm3, so a 1 hp label is a trade description rather than a value that can be checked against this record. Match a condensing unit on its rated capacity at the working evaporating temperature.
Which refrigerant does it use, and can it be recharged with another?
The build AE2430Z-FZ3C is charged with R-404A, and the Z letter in the string is what carries that. The same base with a U letter, AE2430U-ES3C, is an R-290 build. The two are different machines with different maximum continuous current values and must not be substituted for each other. No other refrigerant is printed for this build.
Is AE2430Z-FZ3C the same as AE2430Z-AA3C?
No. Both displace 14.51 cm3 and both run on R-404A, but AE2430Z-AA3C is a 115 V 60 Hz build with a 48 A locked rotor current and an 11 kg mass, against 220-240 V 50 Hz, 21.5 A and 12 kg for the FZ3C build. The part after the hyphen decides the electrical envelope, and it is the part most often dropped when a model is written informally.
What is the difference between AE2430Z and AE2425Z?
AE2425Z-FZ3C displaces 12.01 cm3 and is rated at 2,250 BTU/h; AE2430Z-FZ3C displaces 14.51 cm3 and is rated at 2,700 BTU/h, a step of 20.8 per cent in displacement for 20.0 per cent more printed capacity. The two records are not rated at the same liquid temperature, 32 C against 45 C, so their input power columns cannot be read as an efficiency verdict.
Does the FZ3C suffix change the displacement?
No. All four AE2430 builds displace 14.51 cm3. The suffix changes the supply, the refrigerant in the case of the U build, the mass and the locked rotor current. If a quotation differs only in the suffix, the difference is electrical and market related, not hydraulic.
What evaporating range can it be used over?
Minus 40 C to minus 10 C, which the data sheet prints in both Celsius and Fahrenheit. The published rating point is minus 23 C, so a buyer working at the warm end of the range is working away from the printed capacity and should ask for a rating at the actual condition.
What oil does it take?
Polyolester at 32 cSt, with a charge of 366.3 cm3. The oil type is printed on the same page as the refrigerant and is not a service variable: R-404A is not miscible with mineral oil.
Can I substitute a CAJ or CAE model from this shop?
Not on a model number match. The shop's 24 series pages print their own displacement and horsepower labels, and those labels do not follow the manufacturer's index rule, so 24 in a shop slug is not the same quantity as 24 in a manufacturer string. Match on refrigerant, displacement, supply and rated capacity at the working evaporating temperature.
Where does this site stock the family?
The brand hub carries the Tecumseh range and routes to the reciprocating and rotary families, and the 24 series pages listed in this article carry seller printed displacement and oil data. The exact string AE2430Z-FZ3C has no page on the site at the time of writing, which is why the technical reading in this article is anchored to the manufacturer's own record. Two further entry points help a buyer who arrives without a model number: the full product index groups the catalogue by refrigerant and by family, and the newer write-ups on this site carry the long form treatments of individual models.