Panasonic 4KS280MAA Rotary Refrigeration Compressor
Panasonic 4KS280MAA Rotary Refrigeration Compressor: R407C by the Naming Key, an Undefined Supply Code, and No Printed Row
The string, character by character
The only document in reach that explains how Panasonic builds a rotary compressor part number is the PWAPCGZ room compressor catalogue, and its naming rule page prints three modes. Mode 3 is the one that governs everything outside the older R22 safety-certification set, and it carries a worked example reading 2 P S 156 D 3 E A **. Read against that example, this string resolves like this.
| Position | Mode 3 example | 4KS280MAA | What the key says | Verdict |
|---|---|---|---|---|
| 1 | 2 | 4 | refrigerant type | R407C |
| 2 | P | K | series marking | one of the six series letters |
| 3 | S | S | basic function distinction | standard, not twin piston, not inverter |
| 4 to 6 | 156 | 280 | cylinder volume, integer part | 28.0 cm3 per revolution |
| 7 | D | M | power specification | not in the list |
| 8 | 3 | A | base shape | not in the list |
| 9 | E | A | electric change marking | not enumerated |
| 10 | A | absent | auxiliary management logo | absent |
Three of those positions decode without argument. The series letter K is one of the six the key enumerates, T S R P K V, so it is a real family and not a transcription error. The function letter S is printed in the key as the standard type, so the machine is a fixed speed single piston standard body rather than a twin piston or an inverter. And the three digit field divides by ten, giving 28.0 cm3 per revolution.
The refrigerant digit is the one worth dwelling on, because it is the only part of this string that carries a physical claim about what gas the machine is built for. The key lists six values: 1 R1234yf, 4 R407C, 5 R410A, 6 R134a, 8 R744, and 9 R32. The leading character here is 4, so the key reads R407C.
The catalogue this comes from is the room compressor catalogue published by Panasonic Wanbao Appliances Compressor (Guangzhou), which states on its own opening page that it was founded on 8 June 1993, started production on 1 January 1995, is held 69 per cent by Panasonic and 31 per cent by the Wanbao group, and runs an annual capacity of 11.0 million units. Its naming rule page is the only place the code book is printed, and it is the reason this article can say anything at all about a string that appears in no rating table.
Two characters the key leaves blank, and one it does not need
Position 7 is the supply code, and it is where this string stops being readable. Mode 3 enumerates ten values.
| Code | Supply |
|---|---|
| D | single phase 220 to 240 V, 50 Hz |
| F | single phase 208 V and 230 V, 60 Hz, UL and CSA |
| L | single phase 265 V and 277 V, 60 Hz, UL and CSA |
| E | single phase 220 to 240 V, 50 Hz, VDE and GB |
| S | single phase 100 V, 50 Hz and 60 Hz |
| U | single phase 115 V, 60 Hz, UL and CSA |
| H | single phase 220 V, 60 Hz |
| T | single phase 110 V, 60 Hz |
| Z | three phase DC inverter, certified |
| X | three phase DC inverter, uncertified |
Mode 1, the older R22 set, adds one more, W for three phase 380 V 60 Hz. Neither list contains M.
Mode 2 is no help either. It places a voltage group at a different position and enumerates six values, 225 for 220 V and 220 to 240 V at 50 Hz, 236 for 230 V and 208 to 230 V at 60 Hz, 276 for 265 V and 265 to 277 V at 60 Hz, 126 for 115 V at 60 Hz, 226 for 220 V at 60 Hz, and 385 for three phase 380 V at 50 Hz. The field in this string is 280, which is not one of the six.
So the string fits neither mode completely. Position 7 holds a letter that no printed list defines, and the three digit field that Mode 2 would read as a voltage is a displacement under Mode 3. Trading listings for this part number describe it as a 200 V three phase machine, but the key has no 200 V single character code in Mode 3 and no M at all, so that description cannot be derived from the part number and this article does not adopt it.
Position 8 is the base shape, and the key defines exactly two values, 3 for the standard base and 2 for a special shape. The string carries A, which is neither. That would be a problem for a buyer who needs to know how the machine bolts down, except that the key publishes the foot centre distance by series letter, and the series letter here is readable.
| Series | Foot centre distance |
|---|---|
| T | 60 mm |
| S | 75 mm |
| R | 75 mm |
| K and V | 88 mm |
A K body uses the 88 mm foot spacing. So the one installation fact that position 8 was supposed to carry can be recovered from position 2 instead. That is a small but real recovery, and it is the difference between a string that is merely undocumented and a string that is unusable.
What the catalogue prints at 28.0 cm3 per revolution
The displacement is the number a buyer actually sizes on, so it is worth asking what the catalogue prints at that swept volume. It prints two rows at exactly 28.0, and the nearest K series row sits at 28.2.
| Model | Series | Refrigerant | Displacement | Capacity | Capacity in British thermal units | Input | COP |
|---|---|---|---|---|---|---|---|
| 2VS280L5AA | V | R22 | 28.0 | 4,865 W | 16,599 | 1,500 W | 3.24 |
| 5VS280EZ | V | R410A | 28.0 | 6,820 W | 23,270 | 2,260 W | 3.02 |
| 2K28C225DU | K | R22 | 28.2 | 4,660 W | 15,900 | 1,550 W | 3.01 |
| 2K28C385AUA | K | R22 | 28.2 | 4,665 W | 15,917 | 1,585 W | 2.94 |
All four rows use the same test bench, and all four close arithmetically, which is checked in a later section. What they show is that 28 cm3 is a real, populated point in this product line, and that the capacity at that point depends on the refrigerant rather than on the swept volume. The R22 rows land between 4,660 W and 4,865 W. The R410A row at the same 28.0 lands at 6,820 W.
The nearest K series row to 28.0 is 28.2, which is seven tenths of one per cent away, and it exists under R22 only. There is no K series row at 28.0 under any refrigerant, and no row of any series at 28.0 under R407C.
The R407C page of the catalogue, in full
Since the leading 4 decoded to R407C, the four rows the catalogue prints in that family are the whole of the manufacturer's published position on this refrigerant.
| Model | Series | Displacement | Capacity | Capacity in British thermal units | Input | COP |
|---|---|---|---|---|---|---|
| 4TS023KAA | T | 2.3 | 435 W | 1,484 | 190 W | 2.29 |
| 4RS080SAB | R | 8.0 | 1,315 W | 4,487 | 490 W | 2.68 |
| 4RS102SBA | R | 10.3 | 1,725 W | 5,886 | 590 W | 2.92 |
| 4RS132SAA | R | 13.2 | 2,200 W | 7,507 | 765 W | 2.88 |
The block is four rows long and it carries two series letters, T and R. It carries no K. The largest displacement printed in the family is 13.2 cm3 per revolution, which is less than half of the 28.0 this string would read.
That is the central record fact of this article, and it needs to be stated in the plainest possible form. The refrigerant code decodes to a family whose published lineup stops at 13.2 cm3, and whose series letters do not include the series letter the string carries. The combination is not contradicted by the key, and it is not printed by the catalogue either.
A note on the last column of that block: the catalogue prints COP for these four rows and it recomputes correctly in all four cases, so the family's efficiency figures are internally sound. They are simply lower than anything in the R410A and R32 families, which is what an older high pressure blend looks like when it is compared against a modern one on the same bench.
The shop's Panasonic rotary line, measured
The storefront that this article is written for sells Panasonic rotary compressors, and the extent of that line can be counted rather than guessed. Its sitemap lists 6,150 addresses, of which 101 are Panasonic rotary compressor product pages. All 101 were retrieved for this article, and all 101 carry a printed specification block.
| Prefix digit | Pages | Refrigerant printed on those pages |
|---|---|---|
| 2 | 59 | R22 on 45, nothing on 14 |
| 5 | 33 | R410A on 24, nothing on 8, a drive description on 1 |
| 9 | 9 | R32 on all nine |
| 1, 4, 6 and 8 | 0 | none |
The count is the interesting part. Across 101 pages and 23 distinct family prefixes, three leading digits appear and three refrigerants appear, and among the 78 pages that state a refrigerant at all they map onto each other without a single exception: every 2-prefix page states R22, every 5-prefix page states R410A, every 9-prefix page states R32. Twenty two pages state no refrigerant and one states a drive description instead. No page begins with 1, 4, 6 or 8, and no Panasonic rotary page prints R407C.
That is the strongest independent confirmation of the code book available, because it is a different kind of evidence from the catalogue. The catalogue states the rule once, on a naming page. The shop applies it 78 times across 101 pages, consistently, without ever having been told to.
It also bounds the negative space precisely. The shop's Panasonic rotary line covers three of the catalogue's six refrigerant families. R407C is one of the three it does not carry in this brand, and the string under discussion is an R407C string by its own leading digit.
That is a gap in one brand family rather than a gap in the shop. The same sitemap lists 45 addresses for R407C compressors, all of them scroll machines from a different manufacturer, and two of those pages were opened for this article. One prints 47 cm3 per revolution with 2,860 W of input and 8,980 W of capacity under R407C. The other prints 80 cm3 per revolution with 4,530 W of input and 15,350 W of capacity under the same refrigerant. So an R407C buyer is not being sent away. The combination that does not exist is R407C, at 28 cm3, in a Panasonic rotary body.
The 101 pages sit under the site's Panasonic rotary category, beside the wider rotary compressor category that holds the other rotary families, and one family over from the scroll compressor category. The site's own write-ups are collected in its content index.
There is one further measurement. Four URL forms that a 4-prefix Panasonic rotary page would plausibly use were requested directly, at the site root and under the products directory, in three spellings. All four returned 404. The sitemap contains no address matching 4ks280 and none matching ks280.
Two pages that reproduce a catalogue row exactly
Before treating the rest of the shop's blocks as unreliable, it is worth being fair to the ones that are not. Two pages reproduce a catalogue row to the digit.
| Catalogue row | Shop page | Catalogue figures | Figures printed on the page |
|---|---|---|---|
| 5KS225EA | 5KS225EAA21 | 22.5, 5,400 W, 18,425, 1,920 W, 2.81 | 22.5, 5,400 W, 18,425, 1,920 W, 2.81 |
| 2K28C225DU | 2K28C225DUA | 28.2, 4,660 W, 15,900, 1,550 W, 3.01 | 28.2, 4,660 W, 15,900, 1,550 W, 3.01 |
The second of those two lines is the one that matters most for this article. It is a K series machine, under R22, at 28.2 cm3 per revolution, sitting seven tenths of one per cent away from the displacement this string would read, and the page reproduces the manufacturer's row exactly, down to the coefficient.
So a buyer who wants a Panasonic rotary compressor at roughly 28 cm3 can buy one, with a documented rating, from this shop. What that buyer cannot buy is one in the 4 family, at 28.0, in the K series. The nearest thing that exists is adjacent on two of those three axes.
The first line matters for a different reason. It is the control that proves the site is capable of publishing an accurate block when the block exists in a document. The defects in the next section are therefore not a claim that this seller cannot transcribe numbers. They are a claim about what happens when a page has no row to copy.
Pages whose blocks belong to another string
Five pages carry a block that matches a catalogue row whose model string is not the one the page prints.
| Shop page model row | Block printed on the page | Catalogue row that block matches |
|---|---|---|
| 5KS146EAA21 | 14.7 cc, 1,225 W, 3,505 W | 5PS146EA, 14.7, 3,505 W, 11,959, 1,225 W, 2.86 |
| 5KS205DBB21 | 220.7 CC, 1,685 W, 4,875 W | 5KS205EA, 20.7, 4,875 W, 16,634, 1,685 W, 2.89 |
| 5KS196DAA21 | 24 cm3/rev, 1,600 W, 4,770 W | 5KS196DA, 19.6, 4,770 W, 16,275, 1,600 W, 2.98 |
| 2P17C225ANA, on the 2P17S385AUA page | 16.4, 905 W, 2,800 W and 16.4, 1,090 W, 3,385 W | 2P17S385AUA, 16.4, 2,800 W, 9,554, 905 W, 3.09 and 2P20S385AUA, 19.9, 3,385 W, 11,550, 1,090 W, 3.11 |
Each line in that table is a different kind of slip, and the first is the sharpest. The page's own model field is 146, which by the key's integer rule reads 14.6 cm3. The block beside it prints 14.7. The capacity and input pair, 3,505 W and 1,225 W, matches the catalogue's P series row at 14.7 exactly, including its 2.86 coefficient. So a K series model name is printed above a P series measurement, and the two displacement readings differ in the first decimal place, which is exactly the size of discrepancy that does not announce itself.
The second line is a decimal point that moved. 220.7 CC is not a compressor; it is 20.7 with an extra digit. The capacity and input beside it match the catalogue's 20.7 row to the digit, so the displaced decimal is in the displacement field only.
The third is the same failure in the other direction. The model field 196 reads 19.6, the catalogue prints 19.6, and the page prints 24. The capacity and input match.
The fourth is the most direct: two pages, both with 2P17C225ANA in the model row, carrying two different sets of figures, each of which matches a different catalogue row whose string is not 2P17C225ANA.
Three further fields on the same site are worth recording without interpretation. One page prints DC INVERTER in the refrigerant field, which is a drive description rather than a gas. One prints 3W/W for COP, which is a truncated string rather than a coefficient. One model row carries a trailing xs that no other page carries.
None of these five pages is a 4-prefix page, so none of them says anything directly about this string. They are the reason the article treats every shop block as a seller statement and every catalogue row as the reference, and it is why the two accurate pages above are named rather than assumed.
The shop's own 4-prefix page, and the catalogue's 4-prefix row
The shop does publish one piece of 4-prefix Panasonic material. It is a written page rather than a product page, and its specification table reads as follows, reproduced without editing.
| Field | Value as printed |
|---|---|
| Model Number | Panasonic 4RS080MAA |
| Type | Rotary Fixed Speed Compressor |
| Refrigerant Type | R22 |
| Cooling Capacity | ~13,800 - 14,500 BTU/h |
| Power Supply | 220-240V / 50Hz / 1Ph |
| Displacement | 23.6 cm3/rev |
| Oil Type | Mineral Oil |
Set that against the only 4-prefix row the catalogue prints at a comparable displacement.
| Field | Shop page | Catalogue row 4RS080SAB |
|---|---|---|
| Refrigerant | R22 | R407C, by the key's code 4 |
| Displacement | 23.6 cm3/rev | 8.0 cm3/rev |
| Capacity | 13,800 to 14,500 BTU/h | 4,487 BTU/h |
| Input | not printed | 490 W |
| COP | not printed | 2.68 |
| Test condition | not printed | N-TEC |
Three disagreements, and they do not point in one direction. The refrigerant letter 4 is defined by the key as R407C and the page says R22. The displacement field 080 reads 8.0 by the key's integer rule and the catalogue's own row prints 8.0, while the page says 23.6. And the capacity is roughly three times the catalogue figure at that displacement.
The ratio is the diagnostic. Twenty three point six divided by eight is 2.95, and the midpoint of the printed capacity range divided by 4,487 is about 3.15. A displacement ratio of 2.95 producing a capacity ratio of 3.15 is what a machine of roughly 24 cm3 looks like when compared against a machine of 8.0 on a similar bench. The catalogue's R22 K series carries a 25.2 cm3 row at 4,245 W, which is 14,484 BTU/h, and a 22.5 cm3 row at 3,845 W, which is 13,119. The page's stated range sits between those two rows.
So the page's numbers behave like a 22 to 25 cm3 R22 machine, and its model string behaves like an 8.0 cm3 R407C machine. Neither reading makes the whole table true. Since the page prints no test condition, there is no way to reconcile the two, and this article records the conflict rather than resolving it.
The practical consequence for this string is direct. Anyone searching for a 4-prefix Panasonic rotary compressor on this site will reach that page, and the page will suggest that a 4-prefix Panasonic at 28 cm3 is a 220 to 240 V single phase R22 machine of about 4 kW. The catalogue says a 4-prefix designation means R407C, and that the family's printed lineup stops at 13.2 cm3. Both cannot be right, and the page that a buyer will actually find is the one with no document behind it.
Arithmetic: the catalogue closes, and the shop sometimes does not
Every figure used above can be tested, because each of these documents prints capacity, input and a coefficient side by side. Dividing capacity by input reproduces the coefficient, and multiplying capacity by the standard conversion factor reproduces the British thermal unit column.
| Row | Capacity | Input | COP printed | Capacity divided by input | BTU printed | BTU recomputed | Residual |
|---|---|---|---|---|---|---|---|
| 4TS023KAA | 435 W | 190 W | 2.29 | 2.2895 | 1,484 | 1,484.3 | +0.3 |
| 4RS080SAB | 1,315 W | 490 W | 2.68 | 2.6837 | 4,487 | 4,487.0 | 0.0 |
| 4RS102SBA | 1,725 W | 590 W | 2.92 | 2.9237 | 5,886 | 5,885.9 | -0.1 |
| 4RS132SAA | 2,200 W | 765 W | 2.88 | 2.8758 | 7,507 | 7,506.7 | -0.3 |
| 2VS280L5AA | 4,865 W | 1,500 W | 3.24 | 3.2433 | 16,599 | 16,600.1 | +1.1 |
| 5VS280EZ | 6,820 W | 2,260 W | 3.02 | 3.0177 | 23,270 | 23,270.8 | +0.8 |
| 2K28C225DU | 4,660 W | 1,550 W | 3.01 | 3.0065 | 15,900 | 15,900.6 | +0.6 |
| 2K28C385AUA | 4,665 W | 1,585 W | 2.94 | 2.9432 | 15,917 | 15,917.6 | +0.6 |
Eight rows, eight closures. Every printed coefficient rounds correctly from the two figures beside it, and every British thermal unit value lands within 1.1 units of the recomputation. The conversion factor is therefore the standard 3.412142 throughout, not a rounded shortcut.
That last point is worth a sentence of its own, because it is a negative finding and negative findings are cheap to get wrong. Elsewhere in this article series, a seller's blocks were found to have been filled using a short factor of 3.4, which understated the British thermal unit column by about a third of one per cent. That shortcut does not appear anywhere in these two documents. The catalogue uses 3.412142 and so does every shop block that prints both columns.
The shop's failures are not arithmetic. They are provenance failures: a block that belongs to one row printed under the name of another, which no amount of internal checking can detect, because each such block closes perfectly against itself.
Capacity per cubic centimetre, and the one number this article will predict
Dividing capacity by displacement removes the size of the machine from the comparison and leaves a property that does not depend on swept volume, on supply voltage, or on the part number. Applied across the rows already quoted, it produces this.
| Row | Refrigerant | Series | Displacement | Capacity | Watts per cm3 |
|---|---|---|---|---|---|
| 4RS080SAB | R407C | R | 8.0 | 1,315 W | 164.4 |
| 4RS102SBA | R407C | R | 10.3 | 1,725 W | 167.5 |
| 4RS132SAA | R407C | R | 13.2 | 2,200 W | 166.7 |
| 2K28C225DU | R22 | K | 28.2 | 4,660 W | 165.2 |
| 2VS280L5AA | R22 | V | 28.0 | 4,865 W | 173.8 |
| 5VS280EZ | R410A | V | 28.0 | 6,820 W | 243.6 |
| 5KS225EA | R410A | K | 22.5 | 5,400 W | 240.0 |
| 5KS225HA | R410A | K | 22.5 | 6,670 W | 296.4 |
The R407C rows form a tight band, 164.4 to 167.5, spanning a displacement range from 8.0 to 13.2 without drifting. The R22 row at 28.2 sits inside that band at 165.2 and the R22 row at 28.0 sits just above it at 173.8. The two R410A rows sit far above both, at 240.0 and 296.4.
This is where the article makes its only forward looking claim, and it is labelled as arithmetic rather than as a rating. If the leading 4 in this string means R407C, then a 28 cm3 machine of that type should be expected in the region of 4,600 to 4,900 W of capacity, because that is where every R407C row and every R22 row at that swept volume lands. A listing that quotes R410A-like capacity at 28 cm3 is describing a different refrigerant, or a different displacement, or neither.
Two cautions belong with that. The first is that a capacity prediction from a per cubic centimetre band is not a specification, and no buyer should order against it. It is a sanity range, and its purpose is to tell a buyer when a quoted figure is impossible rather than merely unverified.
The second is visible in the last two rows of the table. Two R410A K series rows at the same 22.5 cm3 print 5,400 W and 6,670 W, which is 23.5 per cent apart, and both carry the N-TEC bench. The catalogue prints no condition that explains the gap. So even within one refrigerant and one series, the per cubic centimetre figure is a distribution and not a constant, which is why the band above is used only to exclude impossible figures.
The six test benches, and why the number needs one
The catalogue prints six standard test conditions, and a capacity figure means nothing without the name of one of them.
| Bench | Condensing | Evaporating | Suction | Liquid | Thermostat |
|---|---|---|---|---|---|
| JIS | 55.0 | 7.0 | 18.0 | 55.0 | 35.0 |
| N-TEC | 54.4 | 7.2 | 35.0 | 46.1 | 35.0 |
| ARI | 54.4 | 7.2 | 18.3 | 46.1 | 35.0 |
| P-RAC | 47.4 | 6.2 | 13.2 | 37.3 | 35.0 |
| Fc | 43.8 | 16.3 | 26.3 | 43.8 | 35.0 |
| Fh | 32.4 | 1.5 | 11.5 | 32.4 | 35.0 |
All figures are degrees Celsius. Every row used in this article carries N-TEC, which is what makes the comparisons across refrigerants and across series legitimate: the two R410A rows at 22.5 cm3, the two R22 rows at 28 cm3, and all four R407C rows were measured against the same condensing, evaporating and suction temperatures.
The distinction between N-TEC and ARI is instructive and it is the reason a buyer has to ask. Those two benches agree on condensing, evaporating, liquid and thermostat temperature and differ only in suction temperature, 35.0 against 18.3, a difference of 16.7 degrees. A lower suction temperature means a denser suction gas, so the same swept volume moves more mass and produces more capacity, and the same pressure ratio over a larger mass flow also costs more input power. A capacity figure can therefore move by several per cent without a single component changing.
The shop prints no test condition on any of its 101 Panasonic rotary pages. That is not specific to this string, and it is the single defect that most limits what a buyer can do with the site's numbers.
What to ask before ordering
| Question | Why it decides something |
|---|---|
| Which document prints a rating row for this exact string? | no catalogue row and no product page does, so every figure in circulation is a seller statement |
| What does position 7 mean, and what supply does it require? | the key's supply lists contain no M, and the trading description of 200 V three phase cannot be derived from the string |
| Is the machine R407C, as the leading 4 says, or R22, as the shop's own page says? | the two imply different capacities at the same swept volume, and one of them implies a family that stops at 13.2 cm3 |
| What is the test condition behind any capacity figure quoted? | without a bench name the figure cannot be compared with anything, including the seller's own pages |
| Which base does it use, and what is the foot centre distance? | position 8 is outside the key's two values, though the K series letter fixes the distance at 88 mm |
| Is a 28.2 cm3 R22 K series machine an acceptable substitute? | it exists, it is documented, and it is in stock under its own model string |
| What is the oil charge and the mass? | the catalogue prints standard accessories and a foot pattern, not a commissioning sheet |
Two standards answer part of that list, and both publish their scope. IEC 60335-2-34 covers the sealed motor compressor as a component, including its protection and control systems, which is the standard a compressor is assessed against on its own. IEC 60335-2-40 covers the assembled system and frames its refrigerant requirements around safety group classification, which is the standard an R407C installation is assessed against once it is built.
Rating practice for capacity claims in North America is set out by AHRI, and refrigerant global warming potential values used in policy comparisons are tabulated by the German Environment Agency. For demand side background, the International Energy Agency's report on the future of cooling sets out the growth curve that air conditioning is on; it is background for this class of machine and it is cited as background only.
A buyer who needs to move from these published figures to a purchase should read the shop's own full product index first, because the site groups its Panasonic rotary pages by refrigerant and the grouping follows the same leading digit that the catalogue's code book defines.
What this article rests on
| Source | What it is | Use in this article |
|---|---|---|
| Panasonic room compressor catalogue, archived capture | manufacturer document | the naming rule and all three modes, the six test benches, every catalogue row quoted, the foot centre distances, and the company facts |
| Panasonic rotary compressor portal, North American site | manufacturer site | the product line's official landing page, which is a script driven shell and prints no 4-prefix string |
| Shop sitemap, 6,150 addresses | site inventory | the count of 101 Panasonic rotary pages, and the absence of any 4ks280 or ks280 address |
| Four candidate 4-prefix product addresses | site inventory | all four returned 404, which is what makes the absence a measurement rather than an assumption |
| Shop page 5KS225EAA21 | seller listing | the control block that reproduces the catalogue's 5KS225EA row exactly |
| Shop page 2K28C225DUA | seller listing | the control block at 28.2 cm3, the nearest documented K series displacement |
| Shop page 5KS146EAA21 | seller listing | a P series block printed under a K series model name |
| Shop page 5KS205DBB21 | seller listing | a displacement field printing 220.7 for a 20.7 machine |
| Shop page 5KS196DAA21 | seller listing | a displacement field printing 24 for a 19.6 machine |
| Shop page 2P17S385AUA and its sibling | seller listing | two pages carrying the same model row and two different blocks |
| Shop page for 4RS080MAA | seller listing, written page | the only 4-prefix Panasonic material on the site, and its conflict with the catalogue |
| Shop Panasonic rotary category page | seller listing | the family grouping that follows the refrigerant digit |
| Shop rotary compressor category page | seller listing | the wider rotary family, and the button target |
| Shop Panasonic scroll category page | seller listing | the neighbouring family, for a reader moving to a different duty |
| Shop product index and content index | seller listing | the full product list, and the site's own write-ups |
| IEC 60335-2-34:2024 | standards body | the component scope for sealed motor compressors |
| IEC 60335-2-40:2024 | standards body | the system scope and its safety group framing |
| AHRI standards | certification body | rating practice for capacity claims |
| German Environment Agency global warming potential table | regulator reference | refrigerant global warming potential values |
| International Energy Agency, the future of cooling | research report | demand side background |
Frequently asked questions
Is 4KS280MAA a real Panasonic part number?
The string is traded. Trading companies list it, marketplace sellers list it, and one Chinese language article describes the 4K series as a product line. What does not exist is a document: the archived manufacturer catalogue prints no K series row under R407C, the manufacturer's North American portal page for rotary compressors carries no 4-prefix string at all, and the Wayback Machine holds no snapshot of any manufacturer model page for this number. A part number that is traded but not documented is a normal situation in this trade, and it means the burden of verification moves to the supplier.
What refrigerant does the leading 4 mean?
R407C. The catalogue's naming rule enumerates six refrigerant values and 4 is R407C, alongside 1 for R1234yf, 5 for R410A, 6 for R134a, 8 for R744 and 9 for R32. This is not an isolated reading: the shop applies the same rule across 101 Panasonic rotary pages, where every 2-prefix page prints R22, every 5-prefix page prints R410A and every 9-prefix page prints R32.
Why does the article not give a capacity figure for this compressor?
Because no document prints one, and the only forward looking number in the article is an arithmetic range explicitly labelled as an expectation. The catalogue's R407C rows and its R22 rows at 28 cm3 all land between 164 and 174 watts per cubic centimetre, which implies a machine in the region of 4,600 to 4,900 W. That is a sanity range for testing a quotation, not a rating.
What does the 280 in the model number mean?
28.0 cm3 per revolution. The naming rule states that the three digit field is the cylinder volume taken as an integer part, so 280 reads 28.0. The catalogue confirms the convention on every row it prints, and it prints two rows at exactly 28.0, one under R22 and one under R410A.
What supply voltage does it need?
The part number does not say, and this is the most useful thing the article can tell a buyer. Position 7 carries an M, and neither of the catalogue's two supply code lists contains an M: Mode 3 enumerates D, F, L, E, S, U, H, T, Z and X, and Mode 1 adds W. The second naming mode puts its voltage group elsewhere and enumerates six codes, none of which is 280. A trading listing that describes the machine as 200 V three phase cannot be checked against the part number, so the supply has to be confirmed from the nameplate.
Is there a K series machine at a similar displacement that I can actually buy?
Yes, under R22. The catalogue prints 2K28C225DU at 28.2 cm3 per revolution, 4,660 W, 1,550 W input and a coefficient of 3.01, and the shop publishes it on its own page with a block that reproduces the catalogue row to the digit. It is seven tenths of one per cent away from 28.0 in displacement and it is a different refrigerant, so it is an alternative rather than a substitute.
Why does the shop's own 4-prefix page disagree with the catalogue?
The page states R22, 23.6 cm3 per revolution and roughly 13,800 to 14,500 British thermal units per hour. The catalogue's 4RS080SAB row states 8.0 cm3 per revolution and 4,487 British thermal units per hour under R407C. The displacement ratio is 2.95 and the capacity ratio is about 3.15, which is what a machine of roughly 24 cm3 looks like beside one of 8.0. The page prints no test condition, so the two cannot be reconciled, and the article records the conflict rather than picking a side.
How reliable are the specification blocks on the rest of the site?
Two of the pages measured here reproduce catalogue rows to the digit, so the site can transcribe accurately when a row exists. Five others print a block that belongs to a different catalogue row, including one where a displacement field reads 220.7 for a 20.7 machine and one where two pages share a model row but not a block. Every one of those blocks closes arithmetically against itself, which is exactly why a coefficient check cannot detect them.
Does the article use the trading listings as evidence?
No. Marketplace and trading company listings establish only that the string is bought and sold, which is a weaker claim than a specification. They were read, they are the reason the string is described as traded, and they are not cited for any figure in this article.
Related Article