HITACHI LS500DH-83D2G R404A Freezer Compressor
Hitachi LS500DH-83D2G R404A Freezer Compressor: The Model String Decodes Completely, the Product Page Contradicts Itself
Key facts at a glance
| Field | Printed value | Where it comes from |
|---|---|---|
| Model | LS500DH-83D2G | product page and catalogue |
| Duty class | low temperature freezer | nomenclature, letter L |
| Refrigerant | R404A | product page, catalogue, nomenclature letter S |
| Displacement | 83 cm3/rev | product page and catalogue |
| Rated motor output | 3,700 W | catalogue |
| Cooling capacity | 7,603 W | catalogue, at condition A |
| Cooling capacity, second unit | 25,966 Btu/h | catalogue |
| Power input | 4,351 W | catalogue |
| Coefficient of performance | 1.75 | computed from the two figures above |
| Drive type | fixed speed | catalogue, and the absence of a motor letter |
| Orientation | vertical | nomenclature, letter H |
| Supply | 380-415 V, 50 Hz, three phase | product page and catalogue |
| Net weight | 36 kg | product page and catalogue |
| Oil | PVE, 1,800 cm3 | catalogue |
| Certificate | CE and CCC | catalogue |
What the shop page prints, and the one pair of figures that disagree
The listing carries two blocks. The numbered summary reads refrigerant R404A, input 4350 W, capacity 25393 Btu/h, voltage 380-415 V at 50 Hz three phase, and an application line. The table below it is headed Product Details and reads model LS500DH-83D2G, displacement 83 cm3/rev, input 4350 W, capacity 7600 W and 25939 Btu/h, refrigerant R404A, the same voltage line, sound level 60 dB, oil 1.8 L, net weight 36 kg, and the same application line.
Nine of those fields are mutually consistent. One is not. The summary says 25393 Btu/h and the details table says 25939 Btu/h, on the same page, in the same listing, one block above the other.
That is not a rounding difference. Dividing 25939 by the printed 7600 W gives a conversion factor of 3.413, which is the ordinary factor to two decimal places. Dividing 25393 by the same 7600 W gives 3.3412, which is the same digits with the middle two transposed. The summary figure looks like a conversion factor that was typed in the wrong order.
The manufacturer prints 25,966 Btu/h against 7,603 W, a factor of 3.4152. So the details table is the closer of the two shop figures to the official value, and the summary block is the outlier. A buyer quoting from the top of the page will quote a capacity that is 2.1 per cent low and that does not reconcile with the wattage printed directly beneath it.
The other fields hold up. Displacement, input, refrigerant, supply, oil charge and net weight all match the technical catalogue, and the capacity in watts is within three watts of the official figure.
The model string decodes completely
The manufacturer publishes a nomenclature page for this family, and every field in the string is defined on it. Reading LS500DH-83D2G from left to right:
| Position | Character | Meaning as printed |
|---|---|---|
| 1 | L | application: L is for low temperature freezer, N is for refrigerated counter |
| 2 | S | refrigerant: S is R404A, and R22 carries no mark |
| 3 to 5 | 500 | specification code, described as output power in HP class multiplied by ten |
| 6 | D | series number, D being the 160 mm frame |
| 7 | H | orientation: H is vertical type, L is horizontal type |
| 8 | none | motor type: V is AC inverter, D is DC inverter, and no indication means fixed speed |
| 9 to 10 | 83 | nominal displacement in cm3 per revolution |
| 11 | D | power source: D is three phase 380 to 415 V at 50 Hz and 440 V at 60 Hz |
| 12 | 2 | pipe connection: 1 is a screw joint, 2 is brazing |
| 13 | none | model type: Y would add an oil balance pipe, and the standard machine carries no mark |
| 14 | G | origin marking, G being Guangzhou |
Two of those fields are worth pausing on, because they are the ones a buyer would otherwise have to ask about.
The first is the application letter. L is the low temperature freezer class, so the description this article was commissioned under, a freezer compressor, is the manufacturer's own classification and not a trade shorthand. A machine in the N class at the same displacement would be a refrigerated counter unit instead, and the two are listed side by side in the catalogue.
The second is the motor position. There is no letter between the H and the hyphen, and the nomenclature says plainly that no indication means fixed speed. That single absence is the whole reason the features block on the product page is wrong, which is taken up below.
The pipe connection digit is also settled rather than guessed. The 2 in this string means a brazed connection, and the catalogue's alternative digit 1 is a screw joint. A buyer preparing a pipe kit can read that off the model number.
Freezer duty is in the string, and the Application field is not
The catalogue's own cover title reads For Refrigeration Application. Its second title, in Chinese, is the more precise of the two and scopes the document to freezing and cold storage duty rather than refrigeration in the broad sense. The nomenclature page then splits that further into the L class for low temperature freezers and the N class for refrigerated counters.
Against that, the product page prints an application line reading AC, drier, refrigeration, chiller, etc. That string appears unchanged on the pages for the 64 cm3 model and the 95 cm3 model as well, and it reads as a category-wide default rather than a statement about this machine. It lists air conditioning first on a compressor whose own model letter says low temperature freezer.
Which of the two a buyer should believe is not a close question. The model letter is part of the identity the manufacturer assigns, and the catalogue title is the scope of the document the ratings are published in. The application line is a listing field that is filled the same way across the family.
The catalogue's operating envelope confirms the same reading. Its envelope charts for this family are drawn across evaporating temperatures that run well below the range an air conditioning scroll is rated over, and the condition this model is rated at has an evaporating temperature of minus 15 degrees Celsius.
The rated row, and the condition behind it
The catalogue prints this model in a block headed fixed speed within the LS series, and the row reads as follows.
| Quantity | Printed value |
|---|---|
| Rated output | 3,700 W |
| Displacement | 83 cm3/rev |
| Phase | 3 |
| Power supply | 380-415/440 V |
| Frequency | 50/60 Hz |
| Motor type | induction motor |
| Overload protection | internal protector and thermostat |
| Scroll profile | involute |
| Weight including oil | 36 kg, 79.4 lbs |
| Oil | PVE |
| Oil charge | 1,800 cm3 |
| Cooling capacity | 7,603 W, 25,966 Btu/h |
| Power input | 4,351 W |
| Certificate | CE and CCC |
The capacity and input are printed against a test condition the catalogue marks as condition A, which it defines on the same page as an evaporating temperature of minus 15 degrees Celsius, a condensing temperature of 45 degrees Celsius, 5 K of subcooling and an 18 degrees Celsius suction temperature.
That detail matters more than it looks. The same catalogue, two pages earlier, prints a separate table of four named industry conditions: the two EN12900 bands and the two ARI 540 bands. Condition A is not one of them. Its evaporating temperature sits between the medium temperature band at minus 10 and the low temperature band at minus 35, and its subcooling is 5 K where all four named bands use zero.
So the ratings in this article are real manufacturer figures at a stated condition, and they are not directly comparable with a table published to EN12900 or ARI 540. A buyer comparing this row against a competitor's EN12900 medium temperature figure is comparing two different tests. The catalogue also prints a condition B on the same page, at minus 6.7 and 48.9 degrees Celsius, which is closer to the ARI 540 medium temperature band but still not identical to it.
The coefficient is the one figure the article computes rather than quotes. Dividing the printed 7,603 W by the printed 4,351 W gives 1.7474, which rounds to 1.75. That is a low temperature coefficient and it should be read as one: a freezer compressor moving 7.6 kW of heat for 4.35 kW of electrical input is performing as a freezer compressor, not as a comfort cooling machine.
The ladder: three sizes, one design
The catalogue prints three fixed speed models in this block, and read together they behave like one design scaled three ways. All of them, and their inverter siblings, sit in the same catalogue branch, which the site files under the Hitachi scroll compressor category.
| Model | Displacement | Rated output | Capacity | Input | COP | Capacity per cm3 |
|---|---|---|---|---|---|---|
| LS350DH-64D2G | 64 cm3/rev | 3,000 W | 5,800 W | 3,410 W | 1.70 | 90.6 W |
| LS500DH-83D2G | 83 cm3/rev | 3,700 W | 7,603 W | 4,351 W | 1.75 | 91.6 W |
| LS600DH-95D2G | 95 cm3/rev | 4,500 W | 8,820 W | 5,050 W | 1.75 | 92.8 W |
Capacity per swept cubic centimetre runs 90.6, 91.6 and 92.8 across a displacement range that grows by half again. That is a spread of 2.2 W per cm3, or 2.4 per cent, which says the three rows are the same thermodynamic design at three sizes rather than three unrelated machines.
Input per cubic centimetre behaves the same way, at 53.3, 52.4 and 53.2 W. The coefficient barely moves, from 1.70 to 1.75 and back, which in practice means that stepping up a size buys capacity at essentially the same efficiency. There is no efficiency argument for choosing the smallest frame and running it hard.
The catalogue also lists inverter models in the same family, and the shop stocks two of them. They carry the same nominal supply as the three rows above, and they still cannot be read as one ladder with them, because the two families are rated at different shaft speeds.
| Stocked inverter form | Displacement | Capacity | Input | COP | Capacity per cm3 |
|---|---|---|---|---|---|
| LS300DHV-47D2G | 56 cm3/rev | 6,500 W | 3,340 W | 1.95 | 116.1 W |
| LS500DHV-80D2YG | 80 cm3/rev | 9,330 W | 5,040 W | 1.85 | 116.6 W |
The 80 cm3 inverter model is three cubic centimetres smaller than this machine and prints 9,330 W against this model's 7,603 W, which is 23 per cent more cooling from less swept volume. That cannot be a better design. Capacity per swept cubic centimetre on the two inverter rows lands within half a watt of the same value, about 116 W, against 90.6 to 92.8 on the fixed speed ladder, and the only way to move that ratio is to turn the shaft faster. The inverter row is a different operating point rather than a better machine, and reading the two as though they came off the same test is the single easiest error to make with this page.
The LS300 row carries a defect of its own. Its model string encodes 47, and its details table prints 56 cm3/rev for the same machine. The table above uses the details value, which is the one that reconciles with the capacity and input printed beside it.
Read the other way, the ladder is a useful argument for the fixed speed machine. On a freezer duty that runs continuously at full load, the inverter's part-load advantage has little to work with, and the fixed speed form avoids the drive electronics entirely.
The shop also carries the oil-pipe forms of the smaller and larger fixed speed machines, the LS350DH-64D2YG and the LS600DH-95D2YG, together with the two inverter models above.
The three-digit code is neither the displacement nor the horsepower
The 500 in the model number is the field most likely to be misread, so it is worth stating what it is not.
It is not the displacement. The displacement is the 83 after the hyphen, and the catalogue confirms it on the row itself.
It is not a clean horsepower readout either, although the nomenclature describes it as output power in HP class multiplied by ten. For this model the arithmetic almost works: 3,700 W divided by 735.5 W per horsepower is 5.03, so the machine is a 5 HP class unit under a 500 code. The same reading works for the largest model, where 4,500 W is 6.12 HP under a 600 code.
It fails on the smallest model. The catalogue prints 3,000 W against a 350 code, and 3,000 W is 4.08 HP, not 3.5. Worse, the catalogue prints three models at 64 cm3 per revolution and 3,000 W rated output under two different codes: the 350 above, and a 400 code on two further 64 cm3 machines in the adjacent block. The same swept volume and the same rated output carry different codes.
The practical rule follows. Order by the displacement digits after the hyphen, which the catalogue confirms on every row, and treat the three-digit code as a frame designation. No document read for this article defines the difference between a 350 and a 400 at the same 64 cm3 and the same 3,000 W, so this article does not decode it and does not guess at it.
The key-features block describes a different machine
The product page carries a block headed Key Features and Advanced Technology with four claims. Each one can be tested against the technical catalogue for this family, and three of the four do not survive.
The block claims advanced gas injection, described as increasing system capacity and shortening temperature response. The catalogue for this family contains no mention of gas injection anywhere in its fourteen pages. That is not a gap in extraction: an exact-phrase search over the full extracted text returns nothing.
The block claims a new asymmetric scroll suitable for APE conditions. The catalogue defines the scroll profile for this model explicitly, and the value it prints is involute. The catalogue does describe a second profile, an algebraic scroll, on the pages for a different series, and uses it as the efficiency argument for that series. Neither profile is described as asymmetric.
The block claims variable speed from 10 to 140 revolutions per second. This machine is in the fixed speed block, carries no speed range row at all, and its model string has no motor letter where an inverter model would carry a V or a D. The catalogue's speed range rows exist only for the inverter models, and they are expressed in hertz, not in revolutions per second. The 10 to 140 figure appears nowhere in the document.
The fourth claim, that the compressor has an oil filter, is not contradicted by the catalogue. It is also not confirmed by it, because the catalogue's LS row has no filtration field. It is left as a claim rather than a fact for that reason.
There is a second such block on the page. The descriptive paragraph above the features says the compressor supports system design for alternative refrigerants, and lists rooftop units, chillers, process cooling and packaged units as applications. The catalogue's scope for this family is R404A freezer and cold storage work. The paragraph is a category-wide text, and it is the same text on the 64 cm3 page and on the 95 cm3 page.
The consequence is practical. A buyer who selects this compressor on the strength of the gas injection claim, or who expects to vary its speed, has been described a machine that the manufacturer's own catalogue does not sell under this model number.
The Y variant, and how to order the right one
Two model strings sit one letter apart and both are real. The nomenclature defines the letter before the final G as the model type field: the standard machine carries no mark, and a Y means the compressor is built with an oil balance pipe for multiple use, meaning parallel operation of more than one compressor on a shared circuit.
So LS500DH-83D2G is the standard machine and LS500DH-83D2YG is the same compressor with an oil equalising connection. Everything else about them is identical in the catalogue, and the shop's two listing pages print identical values for displacement, input, capacity, refrigerant, voltage, sound level, oil and weight. Only the model string differs.
| Model string | Oil balance pipe | Suited to |
|---|---|---|
| LS500DH-83D2G | no | a single compressor on a circuit |
| LS500DH-83D2YG | yes | two or more compressors in parallel |
That is the only difference the sources establish, and it is the difference that decides the order. A buyer specifying a single condensing unit wants the form without the pipe and should not pay for a connection that will be capped. A buyer building a parallel rack needs the Y form, because the alternative is field-fabricating an equalising line on a machine that was not drilled for one.
The same pair exists on the other sizes, and the shop stocks the oil-pipe forms of the 64 and the 95 alongside the standard 95. The full product index is the fastest way to confirm which sizes and forms are listed at any given time, because it enumerates every family the company stocks rather than only the LS ladder above.
Standards, certificates and where the official data lives
The catalogue prints a certificate column, and this model's row reads CE and CCC.
The component standard behind a CE declaration for a sealed motor compressor is IEC 60335-2-34, whose scope limits are 250 V for single-phase motor compressors, 600 V for multi-phase and 600 V for direct-current machines. This machine is three phase at up to 440 V, so it sits inside the 600 V multi-phase limit rather than near either of the other two, and the standard's own scope text is the place to check the exact boundary.
The appliance-level standard that a condensing unit built around this compressor will be assessed against is IEC 60335-2-40, and its current edition states that it does not take into account refrigerants other than groups A1, A2L, A2 and A3 as defined by ISO 817. Which of those groups a given R404A charge falls into is settled by the refrigerant safety data sheet supplied with the order, and no source read for this article states it.
The rating convention that makes one compressor's capacity comparable with another's is maintained by the industry standards body, which publishes the performance rating standards for the HVACR industry. That is the framework that makes condition A worth naming rather than assuming, and it is why the difference between condition A and the four named bands matters.
One more figure belongs here because it decides more freezer projects than any other single number. R404A has a hundred-year global warming potential of 3,922 under the Fourth Assessment Report, 3,943 under the Fifth, and 3,922 under the European F-gas Regulation, on a table published by the German Environment Agency that also records the blend as 44 per cent HFC-125. That is the value a buyer needs when a project's refrigerant charge limit is assessed, and it is high enough that R404A equipment is routinely questioned on environmental grounds.
The broader frame for a freezer project is worth one sentence. The International Energy Agency's report on the future of cooling, published in May 2018, records that using air conditioners and electric fans to stay cool accounts for nearly 20 per cent of the total electricity used in buildings around the world today. That is the demand side of the same ledger that R404A's warming potential sits on the supply side of, and it is the reason a coefficient near 1.75 on a freezer duty is worth attention rather than dismissal.
For anything the catalogue does not print, the manufacturer's own documentation site is the only acceptable substitute. The technical catalogue for this family is published there, and the PDF is downloadable directly, which is where the voltage class, the speed treatment and the condition pair in this article all come from. The shop's own write-ups on individual machines are collected in the news index, sorted by brand and date.
Frequently asked questions
What capacity does the LS500DH-83D2G have?
7,603 W at the catalogue's condition A, which the same row prints as 25,966 Btu/h. The shop page prints 7,600 W, which agrees, but it prints two different Btu figures on the same page and neither is exactly the official one.
What does the L at the start of the model number mean?
The application class. L is the low temperature freezer class, and N at the same position is the refrigerated counter class. So a freezer description of this model matches the manufacturer's own letter rather than a trade shorthand.
What does the S after the L mean?
The refrigerant. S is R404A, and an R22 machine carries no letter in that position. That is why every LS model in this family is an R404A machine and every N model in the same catalogue is not.
Is this a fixed speed or an inverter compressor?
Fixed speed. The motor position in the string is empty, and the nomenclature states that no indication means fixed speed. The catalogue files the row under its fixed speed heading and prints no speed range for it. The inverter models in the same family carry a V for AC inverter or a D for DC inverter in that position.
What does the Y variant change?
It adds an oil balance pipe for parallel use. The shop lists both forms, and they print identical values apart from the model string. Order the form without the Y for a single compressor and the Y form for a multi-compressor rack.
What evaporating temperature is the capacity rated at?
Minus 15 degrees Celsius, against a 45 degrees Celsius condensing temperature, 5 K of subcooling and an 18 degrees Celsius suction temperature. The catalogue calls this condition A and defines it on the page that prints the ratings.
Why does the page show two different Btu figures?
Because the summary block and the details table were filled separately. The details figure of 25,939 converts from the printed 7,600 W at very nearly the standard factor, and the summary figure of 25,393 converts at 3.3412, which is the same factor with two digits transposed. The manufacturer prints 25,966 against 7,603 W.
Does the 500 mean 5 horsepower?
It is close for this model and wrong as a rule. 3,700 W of rated output is 5.03 HP, so the 500 code does fit this machine. But the catalogue prints 3,000 W under a 350 code, where the same reading gives 4.08 HP, and prints three different machines at 64 cm3 and 3,000 W under two different codes.
Where can I compare the rest of the LS range?
The Hitachi scroll compressor category lists the family as stocked, including the inverter models at 47 and 80 cm3 per revolution, and the wider scroll range page covers the other scroll brands in the same branch.
Sources
| Source | Document | Use in this article |
|---|---|---|
| S499 | qishanrcompressor.com product page for Hitachi Refrigeration Compressor LS500DH-83D2G | the nine printed fields, the unnamed second Btu figure, the sound and oil rows, and the two-block disagreement |
| S500 | qishanrcompressor.com product page for LS500DH-83D2YG | the A and B comparison of the oil-pipe form, and confirmation that the two pages print identical values |
| S501 | Hitachi technical catalogue, For Refrigeration Application, scroll compressors, L and N series, document R0000033061 | the rated row, condition A and B, the three-model ladder, the involute profile and the certificates |
| S502 | Hitachi nomenclature page for the L, N and S series, within the same catalogue | the field-by-field decode of the model string, including the L application class and the Y oil-pipe mark |
| S503 | Hitachi documentation index page for the L, N series family | confirmation that LS500DH-83D2G and LS500DH-83D2YG are both current units of this catalogue |
| S504 | qishanrcompressor.com product pages for LS350DH-64D2YG and LS600DH-95D2G | the shop-side ladder figures, the near-exact match on the 64 and the 1.4 per cent offset on the 95 |
| S505 | IEC 60335-2-34, IEC 60335-2-40 and the AHRI performance rating standards | the component scope, the refrigerant grouping clause and the rating framework |
| S506 | German Environment Agency, global warming potentials of selected compounds and their mixtures, Table 4 | the R404A hundred-year values of 3,922, 3,943 and 3,922, and the 44 per cent HFC-125 composition |
| S507 | International Energy Agency, The Future of Cooling, published May 2018 | the building electricity share used in the closing paragraph of the standards section |
HITACHI Scroll Compressor DA84PHDG-D1S2
Related Article