GMCC RKTN150D53UFZ3 Rotary Compressor
GMCC RKTN150D53UFZ3 Heat Pump Compressor: What the Catalogue Prints for the String Without the R
Key facts at a glance
The string RKTN150D53UFZ3 carries a leading R, and in the GMCC naming system that position is the application field, where R means a compressor for heat pumps. The 2024 edition of the manufacturer's rotary compressor catalogue does not print a single row with that prefix. What it prints is KTN150D53UFZ3, a twin-cylinder DC inverter build on R32 at 14.9 cm3, rated 4600 W at 1180 W for a coefficient of performance of 3.90, at a test condition of SEER 60.
| Field | Value | Where it comes from |
|---|---|---|
| String as supplied | RKTN150D53UFZ3 | The enquiry |
| Leading R | Application field, compressor for heat pumps | The naming-rules page |
| Row printed in the 2024 edition | KTN150D53UFZ3 | Page 12, twin-cylinder inverter block |
| Rows printed with the R prefix | None | A scan of the whole edition |
| Series | TN | The series column of the block |
| Refrigerant | R32, R410A | The block heading |
| Drive | DC inverter, twin cylinder | The block heading |
| Test condition | SEER 60 | The block heading |
| Displacement | 14.9 cm3/rev | The row |
| Capacity | 4600 W, printed as 15695 Btu/h | The row |
| Input power | 1180 W | The row |
| Coefficient of performance | 3.90 | The row |
| Run capacitor | Not applicable, printed as a dash | The row |
| Overall height | 270 mm | The row |
| Suction line | 8.1 mm | The row |
| Discharge line | 12.9 mm | The row |
| Supply voltage | Not printed | The block heading has no voltage line |
| Heating capacity | Not printed | SEER is a cooling-season metric |
Two absences matter more than any figure in that table. The edition has no heat-pump row for this displacement, and the row it does have is rated on a cooling-season basis. A heating duty cannot be read off it.
What does the R prefix claim, and what does the catalogue print?
The naming-rules page sits at the front of the catalogue in two panels, and the application-field position is defined there in both Chinese and English.
| Position | Printed in the supplied string | What the naming page says |
|---|---|---|
| Application field | R | Compressors for heat pumps |
| Refrigerant | K | R32 and R410A |
| Series | TN | The series name |
| Displacement | 150 | cm3/rev times ten, so 14.9 is printed as the row value |
| Power and drive | D | DC inverter, which is the drive code of this block |
| Structure | 53 | A two-digit code the naming page does not decode |
| Motor | U | A motor code, not decoded value by value |
| Structure change | F | A structure-change letter |
| Trailing characters | Z3 | Not defined on the naming page |
The decoding produces a coherent model. The problem is that the catalogue does not contain it. A scan of the whole edition for a model string beginning with R returns nothing at all, not one row in any refrigerant block, any drive block or any frequency block. The prefix is defined and never used.
That leaves three possible readings of the supplied string, and the edition supports only the third.
The first reading is that RKTN150D53UFZ3 is a heat-pump build of KTN150D53UFZ3 and shares its numbers. The edition cannot confirm this, because a heat-pump build would be rated on a heating condition and the printed row is rated on SEER 60.
The second reading is that the string is a typographical variant and the intended part is KTN150D53UFZ3. This is the reading the trade most often assumes, and it is the one that gets buyers into trouble, because it silently deletes an application field.
The third reading, and the one this article takes, is that the string names a part the 2024 edition does not document, and the nearest documented neighbour is KTN150D53UFZ3. That neighbour is a real row with a complete set of figures, and it is useful. It is not the same part.
The practical consequence is a single question to the manufacturer: does the R build exist, and what is its heating rating. Until that is answered, the numbers in this article belong to the base row and should be quoted with the base string attached.
What does the base row print?
The row, transcribed from page 12 of the 2024 edition, reads:
KTN150D53UFZ3 14.9 4600 15695 1180 3.90 - 270 8.1 12.9
Read in the order of the column headers, that is the typical model, the displacement, the cooling capacity in watts, the same capacity in Btu/h, the power input, the coefficient of performance, the run capacitor, the overall height, the suction line and the discharge line.
Three closures hold. 4600 divided by 1180 is 3.898 and the table prints 3.90. 4600 multiplied by 3.412 is 15695.2 and the table prints 15695. And 14.9 cm3/rev at 50 revolutions per second sweeps 745 cm3 per second, which puts the input at 1.584 W per swept cm3.
| Field | Printed | What a buyer can do with it |
|---|---|---|
| Displacement | 14.9 cm3/rev | Sizes the machine against a required volume flow |
| Capacity | 4600 W at SEER 60 | Compares with other rows in the same block only |
| Input | 1180 W | Sizes the electrical feed only after the voltage is known |
| COP | 3.90 | A seasonal ratio, not a single-point ratio |
| Capacitor | printed as a dash | No run capacitor, which is normal for an inverter drive |
| Height | 270 mm | Enclosure and mounting |
| Suction | 8.1 mm | Piping |
| Discharge | 12.9 mm | Piping, and the field that separates this platform from the smaller-bore blocks |
| Voltage | absent | Must come from the manufacturer |
| Mass, oil, current, speed, sound | absent | Must come from the specification document |
The dash in the capacitor column is worth explaining rather than skipping. In this catalogue the fixed-speed blocks print a microfarad and voltage pair there, and the inverter blocks print a dash, because the drive board replaces the run capacitor. A reader who treats the dash as missing data will go looking for a capacitor that does not exist.
The discharge line is the second field worth reading carefully. Every row in this twin-cylinder block prints 12.9 mm, while the single-cylinder block on the facing page mixes 9.8 and 12.9. The discharge size therefore separates cylinder architecture in this edition rather than capacity, and a piping design that was built for a 9.8 mm machine does not transfer.
Why is the rating on SEER 60, and what does that leave out for a heat pump?
SEER is a seasonal energy efficiency ratio. It is computed over a cooling season at a set of part-load points, and it produces a single number that describes how a machine behaves across a range of outdoor temperatures rather than at one. The whole twin-cylinder inverter block is rated this way, and the heading says so in one line.
That is the right basis for an air-conditioning machine and the wrong basis for a heating claim. Two things follow.
First, a SEER rating is not a capacity. The 4600 W printed in the row is the capacity figure that accompanies the seasonal ratio in this edition, and it is not the same thing as a heating capacity at a stated outdoor temperature. Nobody should carry 4600 W into a heat-pump sizing calculation as though it were a heating output.
Second, the efficiency number is not transferable. A seasonal cooling ratio of 3.90 says nothing about behaviour at low ambient in heating mode, which is where a heat-pump build earns or loses its case. The catalogue prints no heating capacity, no heating coefficient of performance, no low-ambient envelope and no defrost data for this row.
So if the R prefix is real, the most important number about this compressor is the one the edition does not contain. That is not a gap in the research; it is a property of the document, and it is stated here so that a reader does not fill it with an assumption.
Four builds at 14.9 cm3, and what separates them
The 14.9 displacement is printed four times in the same block, all on R32 and R410A, all at SEER 60. Reading the four rows together is the most informative thing a buyer can do with this page, because it isolates what the letter code after the displacement actually changes.
| Model | Displacement | Capacity W | Input W | COP | Height mm | Remark |
|---|---|---|---|---|---|---|
| KTN150D35UFT4 | 14.9 | 4720 | 1240 | 3.81 | 280 | none |
| KTN150D53UFZ3 | 14.9 | 4600 | 1180 | 3.90 | 270 | none |
| KTN150D43UFZ31 | 14.9 | 4600 | 1185 | 3.88 | 270 | under developing |
| KTN150D63UFZ3 | 14.9 | 4600 | 1165 | 3.95 | 270 | none |
Three of the four print exactly 4600 W and exactly 15695 Btu/h, and they differ only in input: 1165 W, 1180 W and 1185 W. That is a spread of 20 W, or 1.7 per cent, and it produces a coefficient of performance that moves from 3.88 to 3.95. The capacity column is constant to the last digit, so the difference cannot be a size difference. It is a build difference inside one swept volume.
The fourth row is a different capacity point. It prints 4720 W at 1240 W, which is 2.6 per cent more capacity for 5.1 per cent more input, and its coefficient of performance drops to 3.81. It also stands 280 mm tall rather than 270 mm.
Three practical rules follow from that table, and each of them has a use at quotation time.
A capacity quoted without the full string is ambiguous. 4600 W describes three different builds with three different inputs, so a quotation that says 4600 W has not yet said which machine is being sold.
The best coefficient of performance in the group belongs to the lowest input, not to the highest capacity. KTN150D63UFZ3 prints 3.95 on 1165 W, while the row with the most capacity prints 3.81. On a seasonal basis the smaller-input build wins.
The row marked under developing sits in the middle of the group. KTN150D43UFZ31 is flagged while its neighbours are not, which means the release status has to be checked per string and cannot be inferred from the displacement.
Where does 14.9 sit in the KTN ladder?
The block runs from 11.5 to 21.2 cm3 across six KTN rows with the KTM block continuing above it. Holding refrigerant, drive and condition constant makes the ladder a clean one-variable comparison.
| Model | Displacement | Capacity W | Input W | COP | Height mm | Suction mm | Discharge mm | Remark |
|---|---|---|---|---|---|---|---|---|
| KTN130D53UFZ3 | 13.1 | 4015 | 1035 | 3.88 | 270 | 8.1 | 12.9 | none |
| KTN150D35UFT4 | 14.9 | 4720 | 1240 | 3.81 | 280 | 8.1 | 12.9 | none |
| KTN150D53UFZ3 | 14.9 | 4600 | 1180 | 3.90 | 270 | 8.1 | 12.9 | none |
| KTN150D43UFZ31 | 14.9 | 4600 | 1185 | 3.88 | 270 | 8.1 | 12.9 | under developing |
| KTN150D63UFZ3 | 14.9 | 4600 | 1165 | 3.95 | 270 | 8.1 | 12.9 | none |
| KTN180D61UFZ3 | 18.0 | 5730 | 1558 | 3.68 | 280 | 9.8 | 12.9 | under developing |
| KTN210D61UFUC3 | 21.2 | 6675 | 1815 | 3.68 | 280 | 9.8 | 12.9 | none |
Capacity per cm3 of displacement runs 306.5 at 13.1, then 308.7 on this row, then 318.3 at 18.0 and 314.9 at 21.2. The curve rises with size and then turns over, which is the usual shape for a rotary family, and it means the 14.9 point is not the most capacity-dense in the block. The 18.0 row is.
Input per swept cm3 behaves the other way. It runs 1.580 at 13.1, 1.584 on this row, 1.731 at 18.0 and 1.712 at 21.2, so the larger machines spend more power per unit of swept volume and buy back capacity through the swept volume itself. That is visible in the coefficient of performance falling from the 3.88 to 3.95 band at 14.9 down to 3.68 at 18.0 and above.
Two fields change at the same time as the size, and both belong in a selection note. The suction line steps from 8.1 mm to 9.8 mm above 14.9, so the piping does not carry over to the 18.0 row. And the remark column flags KTN180D61UFZ3 as under developing, so the largest released row in this block is not the largest printed row.
What do the supplier pages print?
The supplier site carries pages for several strings in this family and none for the string in this article. Reading what is there is still worthwhile, because it shows what the trade is being offered and where the pages disagree with the edition.
| String | Page status | What the 2024 edition prints for it |
|---|---|---|
| KTN110D42UFZ | page present | No KTN110 row exists in the edition |
| KTN150D30UFZ | page present | No such row, the 14.9 group is D35, D53, D43 and D63 |
| KTN150D42UFZ | page present | No such row |
| KTM180D57UMT | page present | No such row, the edition prints KTM180D43UMT and KTM180D68UFT |
| KTN150D53UFZ | page not found | The edition prints KTN150D53UFZ3, with the trailing 3 |
| KTN150D53UFZ3 | no page | Page 12, the row this article documents |
| RKTN150D53UFZ3 | no page | No R-prefixed row anywhere in the edition |
Four of the strings the site lists do not appear in the 2024 edition at all. That is not automatically a defect, since a supplier may carry a build the catalogue omitted or a later revision of one, and the edition itself warns that the data is for reference. It does mean that a page is not a substitute for a row.
Three things on those pages mislead in a way that a quick read will not catch.
The pages for KTN150D30UFZ and KTN150D42UFZ print identical sheets. Same displacement, same capacity, same input, same coefficient of performance, same photograph and the same four key-feature lines. Two different strings cannot both be right if they are the same machine, and at least one of the two pages is carrying the other one's numbers.
A third page is arithmetically tidy and still describes a machine the edition does not contain. KTN110D42UFZ prints 11 cm3 at 885 W for a coefficient of performance of 3.92, and 885 W at 3.92 is 3469 W, or 11837 Btu/h against the 11823 printed on the page. KTM180D57UMT prints 18 cm3 at 1494 W for 3.73, and 1494 W at 3.73 is 5573 W, or 19015 Btu/h against the 19005 printed. Both close within rounding. The displacement is what does not match: no KTN110 row appears anywhere in the edition, and both KTM180 rows in it are printed at 17.6 cm3.
The voltage field on all of these pages is filled with the drive description rather than a voltage, so a reader looking for a supply finds the words DC Inverter Twin Cylinder. That field is the one place a buyer would look first, and it is the one place the pages do not answer.
How should a buyer specify the heat-pump build?
Six checks, in order. The first two exist because of the prefix, and the rest are the ordinary work.
| Step | What to confirm | Why it decides the order |
|---|---|---|
| 1 | Whether an R build exists, in writing | No R-prefixed row exists in the 2024 edition |
| 2 | The heating rating and the condition it is measured at | The printed row is rated at SEER 60, which is cooling |
| 3 | The full string, including the two digits after D and the trailing Z3 | Four builds share 14.9 cm3 and three share 4600 W |
| 4 | The supply voltage | The block heading has no voltage line and the pages put the drive in that field |
| 5 | Release status | One member of the 14.9 group is flagged under developing |
| 6 | The specification document for mass, oil, current and speed | None of these is printed in the row |
The order is not cosmetic. Checking the voltage before the prefix produces a confirmed supply for a part whose existence is unconfirmed. Checking the heating rating first tells the buyer whether the rest of the exercise is worth doing at all.
For a tender the useful wording is to require the manufacturer's own data sheet naming the application field and the heating condition, because neither is in the catalogue and both change the answer. A quotation that offers 4600 W without naming SEER 60 cannot be compared with one that offers a heating capacity at a stated outdoor temperature, and the two numbers are not the same kind of number.
Where can this row be checked?
The row is on page 12 of the 2024 edition of the manufacturer's rotary compressor catalogue, in the twin-cylinder DC inverter block on R32 and R410A. The same edition prints the naming-rules page at the front, which is where the R prefix is defined, and the single-cylinder block on page 11, which is the neighbouring architecture.
The catalogue is distributed through the manufacturer's product centre and through the downloads page on the manufacturer site, and a distributor-hosted copy of the 2024 manual is available for readers who want a second host for the same file.
For the family context rather than the single row, the site's GMCC rotary compressor range page and the category overview place this model inside the wider rotary compressor category, and the GMCC brand index collects the models from this manufacturer that the site carries. A 14.9 cm3 build also sits at the size where rotary and scroll architectures start to overlap, and the GMCC scroll line is where that comparison begins; it is a different architecture with its own catalogue, so the numbers do not transfer. The same page structure read at a different refrigerant letter is worked through in the R410A example on the blog side. None of those pages carries the rating.
Which standards and approvals frame the purchase?
A rotary compressor of this class is certified as a motor-compressor, and the safety standard a test house cites for that component is IEC 60335-2-34, which is the part of the household appliance series written for motor-compressors. Naming the standard is not a certification statement. This article makes no claim that RKTN150D53UFZ3 or KTN150D53UFZ3 holds any certificate, because the row prints no approval marks.
On the refrigerant side, a machine using R32 and placed on the European market falls under Regulation (EU) 2024/573, the framework that governs fluorinated gases and the equipment containing them. The regulation is cited here as the framework a compliance team will work from, not as a statement about this model's charge or classification.
On the duty side, a heat-pump build is bought for a heating season rather than a cooling one, and the seasonal argument that makes the distinction matter is set out in the IEA's The Future of Cooling. This article takes the direction of that argument and none of its numbers.
Frequently asked questions
Is RKTN150D53UFZ3 in the 2024 catalogue?
No. The edition prints KTN150D53UFZ3 on page 12 and contains no row with an R prefix anywhere in the book. The prefix is defined on the naming-rules page as the heat-pump application field, so the string is well formed and undocumented. Treat it as a part to be confirmed with the manufacturer, not as a catalogue row. The news index on this site is where a revised edition would be announced.
What does the leading R mean?
It is the application-field position, and R means a compressor for heat pumps, as against a blank field for air conditioning, L for freezing and cold storage, E for heating and G for cabinet air conditioning. The position is defined in both Chinese and English on the naming page. What the edition does not do is print any model that uses it.
Can I use 4600 W as a heating capacity?
No. The 4600 W in the row is the capacity that accompanies a SEER 60 rating, which is a cooling-season basis. A heating capacity is quoted at a stated outdoor temperature with a stated water or air condition, and the edition prints no such figure for this displacement. Carrying 4600 W into a heating calculation is an assumption, not a reading.
What is SEER 60 in this catalogue?
It is the test condition heading of the whole twin-cylinder inverter block on page 12, printed as Test Condition: SEER 60. It denotes a seasonal energy efficiency ratio computed over part-load points rather than a single-point measurement. Every row in that block, including all four 14.9 cm3 builds, is rated on that basis.
Why do three different builds print the same capacity?
Because the capacity column in this block is constant across the three and the difference sits in the input. KTN150D53UFZ3 prints 1180 W, KTN150D43UFZ31 prints 1185 W and KTN150D63UFZ3 prints 1165 W, all at 4600 W and 15695 Btu/h. The letters after the displacement change the build, and the build changes the input, so the coefficient of performance moves from 3.88 to 3.95 while the capacity does not move at all.
Which build in the 14.9 group has the best coefficient of performance?
KTN150D63UFZ3 at 3.95, on the lowest input of the three constant-capacity builds. The row with the most capacity, KTN150D35UFT4, has the lowest ratio at 3.81, because it buys 2.6 per cent more capacity with 5.1 per cent more input. On a seasonal basis the lower-input build is the better one.
Is there a page for KTN150D53UFZ3 on the supplier site?
No. The site's index carries two KTN150 pages, for the D30UFZ and D42UFZ strings, and neither matches this row. A direct request for the D53UFZ string without the trailing 3 returns a page-not-found response. The page that does exist for D42UFZ and the one for D30UFZ print identical sheets, so neither can be used to cross-check this row.
What is missing from the row?
Mass, oil type and charge, locked rotor and running current, rated speed, sound pressure level, a second operating point, the joint type and any approval mark. The supply voltage is also absent, because the block heading prints only the refrigerant, the drive and the test condition. All of these have to come from the specification document.
What supply does this compressor need?
The catalogue does not say. The block heading on page 12 prints R32 and R410A, DC Inverter Twin Cylinder and SEER 60, and no voltage line at all, which is a difference from the fixed-speed blocks where the voltage sits in the column heading. The supplier pages put the drive description in their voltage field, so they do not answer it either. Ask the manufacturer.
Sources
| # | Source | What it provided |
|---|---|---|
| S1 | GMCC rotary compressor product manual, 2024 edition | The base row, the four 14.9 cm3 builds, the KTN ladder, the naming-rules page and every figure printed in this article |
| S2 | GMCC official product centre | Family positioning for the TN series inside the rotary range |
| S3 | GMCC official downloads page | The entry point for the current edition of the manual |
| S4 | Supplier product pages named in this article | The strings the trade lists, the duplicate sheets and the fields that disagree with the edition |
| S5 | Supplier sitemap and GMCC category pages | Which strings have a page and which do not |
| S6 | IEC 60335-2-34 | The standard a test house cites when it certifies a motor-compressor |
| S7 | Regulation (EU) 2024/573 and the IEA report on cooling demand | The refrigerant framework and the demand context, neither of which supplies a number used here |