KSG165V1UMT GMCC Rotary Air ConditionerCompressor
GMCC KSG165V1UMT Rotary Compressor: 4,285 W at the ARI Condition, and a 165 Code Whose GX Twin Prints 21 Per Cent More
GMCC prints KSG165V1UMT once, on page 14 of the 2024 rotary compressor catalogue, in the SG group of the green refrigerant section: R32, single phase 50 Hz 220/240 V, at the ARI test condition, displacing 16.7 cm3/rev and rated 4,285 W on 1,440 W for a printed coefficient of 2.98. The same three digits are also printed on the next page against a different build, which prints 5,185 W
Key facts at a glance
| Field | What the 2024 catalogue prints | Where it comes from |
|---|---|---|
| Model string | KSG165V1UMT | PDF page 9, right half, printed page 14, one row only |
| Series | SG | series label printed in the left column of the same block |
| Section | GREEN REFRIGERANT COMPRESSOR | section title printed at the head of the page |
| Refrigerant | R32 | block header on the same page |
| Supply | 1ph, 50 Hz, 220/240 V | block header on the same page |
| Test condition | ARI | block header on the same page |
| Displacement | 16.7 cm3/rev | row |
| Cooling capacity | 4,285 W, printed also as 14,620 Btu/h | row |
| Power input | 1,440 W | row |
| Coefficient of performance | 2.98 | row |
| Run capacitor | 40/400 | row |
| Height | 310 mm | row |
| Two pipe diameters | 9.8 mm and 16.2 mm | row, column headings are set as graphics |
| Development status | in production, no triangle in the last column | row |
| Document | GMCC Rotary Compressor Product Catalog, 2024 edition, 20 PDF pages, 2,990,900 bytes | the file itself, md5 5c58f3bf5681501f481fd8396febc207 |
Everything in the table above is a printed value except the page mapping and the file check, which are structural facts about the document and are explained in the next section. Nothing in this article is taken from a distributor listing, a marketplace page or a memory of the product.
Is KSG165V1UMT in the GMCC 2024 catalogue?
Yes, and the string appears exactly once across the twenty pages. The catalogue is laid out as spreads, so each PDF page carries two printed pages side by side and prints both folio numbers at the foot. The model sits on PDF page 9, in the right half, and the folio printed at the bottom right of that half is 14. The left half of the same PDF page is printed page 13. The mapping holds for the whole file: PDF page N carries printed pages 2N-5 and 2N-4, which is why a text search that reports a hit without its x-coordinate will put the row on the wrong page.
The two halves are independent tables with their own header bands, and they do not share a test condition. On PDF page 9 the left band prints R32 over single phase 50 Hz 220/240 V at the condition the catalogue codes GX, and the right band prints R32 over single phase 50 Hz 220/240 V at the condition it codes ARI. Same gas, same supply, one word different in the header, and the two blocks behave very differently. Reading a row without reading the band above it is the first way to go wrong on this page.
The row is in production. The catalogue marks units still under development with a filled triangle in the last column and prints the legend on every page that carries the mark, in both languages, as a note that products carrying the triangle are under development. The KSG165V1UMT row carries no triangle, and neither do the two SG rows beside it. Four rows on that page do carry it, three of them KSN inverter entries in the left half and one KSF row in the right half, so the mark is doing real work rather than decorating the layout.
Twenty rows in the document carry a KSG string, and they are spread over four printed pages rather than one: three on page 13, three on page 14, ten on page 15 and four on page 17. Only one of those twenty is this model. Anyone comparing KSG numbers collected by search needs to establish which of the four pages each number came from before putting two of them in the same sentence, because three of the four pages are printed at conditions other than ARI.
The row as printed, and the arithmetic that closes it
The row prints nine values after the model string. Only a few of the column headings survive in the text layer of this block; the rest are set as graphics, which is why the field list below is reconstructed from what each value can only be. The reconstruction is not guesswork, because five of the nine values pin each other down arithmetically.
| Position | Printed value | Field |
|---|---|---|
| 1 | 16.7 | displacement, cm3/rev |
| 2 | 4,285 | cooling capacity, W |
| 3 | 14,620 | cooling capacity, Btu/h |
| 4 | 1,440 | power input, W |
| 5 | 2.98 | coefficient of performance, W/W |
| 6 | 40/400 | run capacitor, microfarad and volt AC |
| 7 | 310 | compressor height, mm |
| 8 | 9.8 | pipe diameter, mm |
| 9 | 16.2 | pipe diameter, mm |
Four identities hold on these numbers, and each one is a test that a transcription has been made correctly:
Dividing 4,285 W by 1,440 W gives 2.9757, against the printed 2.98. Multiplying 4,285 W by 3.412 gives 14,620.4 Btu/h, against the printed 14,620. Dividing 4,285 W by the 16.7 cm3/rev swept volume gives 256.6 W of cooling for every cubic centimetre turned per revolution. Dividing 1,440 W by 16.7 times 60, the cubic centimetres swept per second at 60 revolutions per second, gives 1.4371 W drawn for every cubic centimetre per second swept through the machine.
Those last two numbers matter more than the raw watts, because they are the only way to put two rows on the same footing when the catalogue prints them at different displacements. A capacity in watts says nothing on its own. Watts per swept cubic centimetre says how hard the machine is being driven, and watts per swept cubic centimetre per second says how much electricity each cubic centimetre of swept gas costs. Both ratios are used below to compare rows that a buyer might otherwise compare by wattage alone.
The row also carries a run capacitor of 40 microfarad at 400 V AC and a height of 310 mm. Those two fields are the ones a builder needs before the compressor arrives and the ones a summary line almost always drops. The 310 mm is not constant across the family: three rows in the SG group share it, but the 28.0 cm3/rev row on the facing page prints 344 mm, so a dimensional drawing cannot be borrowed across the group.
What the ARI condition does to every number on this row
The word ARI in the header band is the whole reason this row looks weak beside its own siblings. The catalogue marks every block with a condition code, and it prints the same family under at least three of them. Because the hardware does not change across those blocks, the difference between them can be measured directly from the printed figures.
The cleanest measurement is capacity per swept cubic centimetre, which cancels the displacement. Across all twenty KSG rows in the document the ratio separates into three bands that follow the condition code rather than the size:
| Condition | Where it is printed | Rows | Capacity per cm3 |
|---|---|---|---|
| ASH | page 17 | KSG180V1SFT, KSG240V1SMV | 250.0 to 257.9 W |
| ARI | page 14 | KSG165V1UMT, KSG185V1UKU, KSG230V1UKU | 256.6 to 259.6 W |
| GX | pages 13 and 15 | the ten S1 rows and the three larger page 13 rows | 302.5 to 314.2 W |
| GX at 60 Hz | page 17 | KSG230N1VMT, KSG280N1VMT | 372.3 to 380.8 W |
The 60 Hz pair is separated out because it changes two things at once. The other three bands are all single phase at 50 Hz, and they still separate cleanly, which is what makes the condition the explanation rather than the frequency.
The narrowest comparison in the whole document holds the displacement and the supply fixed and changes only the condition. Take the 22.9 cm3/rev rows: KSG230V1UKU prints 5,945 W on 1,980 W at ARI, which is 259.6 W per cm3 and a coefficient of 3.00, while KSG230S1VMU prints 7,110 W on 1,655 W at GX, which is 310.5 W per cm3 and a coefficient of 4.30. Same displacement, same frequency, same phase. Capacity rises 19.6 per cent, power falls 16.4 per cent, and the printed coefficient rises by more than two fifths.
That is not a measurement error and it is not a better compressor. It is the same machine rated on a different bench. The ARI row draws more electricity for less cooling, which is what a harsher set of evaporating and condensing temperatures produces. The consequence for a buyer is concrete: the 2.98 printed on this row is an ARI-condition coefficient, and it cannot be set beside a GX-condition coefficient from the next page as though the two were the same quantity.
The SG block: three rows printed on one condition
The SG group on printed page 14 has exactly three rows, all three printed at the ARI condition, and in this block the ladder is unusually well behaved. Capacity per swept cubic centimetre moves by 1.2 per cent across a displacement range of 37 per cent, which means the catalogue is scaling one design rather than switching architecture between sizes.
| Model | Displacement | Capacity | Power | Coefficient | W per cm3 | W per cm3/s |
|---|---|---|---|---|---|---|
| KSG165V1UMT | 16.7 cm3/rev | 4,285 W | 1,440 W | 2.98 | 256.6 | 1.4371 |
| KSG185V1UKU | 18.5 cm3/rev | 4,775 W | 1,605 W | 2.98 | 258.1 | 1.4459 |
| KSG230V1UKU | 22.9 cm3/rev | 5,945 W | 1,980 W | 3.00 | 259.6 | 1.4410 |
Specific capacity runs 256.6, 258.1 and 259.6, a spread of 1.2 per cent. Specific power runs 1.4371, 1.4459 and 1.4410, a spread of 0.6 per cent. That is what a straight ladder looks like in printed data, and it has a commercial consequence that runs against intuition: stepping up from 16.7 to 22.9 cm3/rev buys 39 per cent more cooling capacity for 37.5 per cent more electricity, with no efficiency penalty and no efficiency gain. A designer who picks the smallest row to save energy is choosing the wrong lever. The only thing the smallest row buys is envelope.
The three rows also differ in the capacitor, 40/400 on the two smaller rows and 45/400 on the 22.9, which is a starter-component difference a panel builder has to know about before ordering. The height holds at 310 mm on all three, but the second pipe diameter splits: 16.2 mm on the 16.7 and the 22.9, and 12.9 mm on the 18.5. A shared height and a shared capacitor do not imply a shared connection size.
The same 165 code, printed twice, at two conditions
This is the trap in this family, and it is worth a table because the two rows look interchangeable until they are put side by side. The three digits 165 appear on two different builds, one printed on page 14 and one on page 15, and the two are not two versions of the same specification.
| Field | KSG165V1UMT | KSG165S1VMT | Difference |
|---|---|---|---|
| Printed page | 14 | 15 | different block |
| Supply code | V, single phase 50 Hz 220/240 V | S, single phase 50 Hz 230 V | different supply |
| Test condition | ARI | GX | different bench |
| Displacement | 16.7 cm3/rev | 16.5 cm3/rev | minus 0.2 |
| Capacity | 4,285 W | 5,185 W | plus 21.0 per cent |
| Power input | 1,440 W | 1,200 W | minus 16.7 per cent |
| Coefficient | 2.98 | 4.32 | plus 45.0 per cent |
| Capacity per cm3 | 256.6 W | 314.2 W | plus 22.4 per cent |
| Capacitor | 40/400 | 40/400 | same |
| Height | 310 mm | 310 mm | same |
Two rows, one nominal class, a 21 per cent gap in capacity and a 45 per cent gap in the printed coefficient. The capacitor and the height are identical, which tells a buyer that the two builds are physically close and makes the numbers look more comparable than they are. The supply code differs by one letter, and that one letter is doing twice the work: it moves the supply from 220/240 V to 230 V and, in this family, it comes with the GX bench rather than the ARI one.
The displacement line is the quieter finding. The code is 165 for both, and the printed displacement is 16.7 for one and 16.5 for the other. Across the twenty KSG rows the printed displacement sits within 0.2 cm3/rev of the code divided by ten, sometimes above and sometimes below: eleven of the twenty are exactly equal, seven sit 0.1 away and two sit 0.2 away. The code is a nominal class rounded to the nearest half cubic centimetre, not a displacement carried to one decimal place, and the row is the authority.
Reading the string: K, SG, 165 and V
The catalogue prints its naming rules on printed pages 5 and 6, and four of the characters in KSG165V1UMT can be checked against that page and then against the printed block header, which is a much stronger test than reading the rule table alone.
| Characters | The naming rules say | Checked against |
|---|---|---|
| K | refrigerant code for R32 and R410A | the block header on page 14 prints R32 |
| SG | series name | the series label printed beside the row |
| 165 | displacement in cm3/rev multiplied by ten | the row prints 16.7, the page 15 row prints 16.5 |
| V | single phase, 50 Hz, 220/230/240 V | the block header prints 1ph, 50 Hz, 220/240 V |
| 1, U, M, T | motor specification, structure change, conditions of use, accumulator and base geometry | not decoded in this article |
The K check is worth spelling out, because it settles a question the shop pages raise. The naming page lists S as the code for R404A and K as the code for R32 and R410A, as two separate entries in the same refrigerant table. A string beginning with KSG therefore cannot be an R404A machine under the manufacturer's own rules, whatever any listing field says.
The V check is the one that makes the rest of the family readable. The naming page lists the power codes as an ordered run, and the same ordering works on four separate printed blocks in this document: V gives single phase 50 Hz at 220/230/240 V, S gives single phase 50 Hz at 230 V, N gives single phase 60 Hz at 208 to 230 V, and the three phase codes sit in their own run. Reading KSG230V1UKU, KSG230S1VMU and KSG230N1VMT side by side is a direct demonstration: three rows, one displacement, three supplies, three different sets of numbers.
What is not decoded here is the run of characters after the power letter. The naming page assigns positions for motor specification, structure change, conditions of use and accumulator geometry, and a reader can see that KSG165V1UMT and KSG165S1VMT differ at exactly those positions, but the catalogue does not print a table that maps a numeral in that position to a single meaning. Treating 1UMT as a decoded suffix would be an invention, so this article does not.
The duty field also deserves a line, because it answers the description in the request. The naming page lists an application field whose default entry is compressors for air conditioning, with separate markers for heat pumps, freezing and cold storage, heating and cabinet air conditioning. KSG165V1UMT carries no such marker, so under the manufacturer's own table it is a default air-conditioning compressor. It is not a freezer compressor and no field on the row supports that reading.
Where one sibling row fails to close
A twenty-row family is a large enough sample to audit every row against itself, and the audit is the cheapest quality check available on a document that is set largely as graphics. Dividing the printed capacity by the printed power input and comparing against the printed coefficient passes nineteen of the twenty rows. The rows below are printed at four different conditions, ARI, GX, ASH and GX at 60 Hz, so the capacities in the table are not comparable with each other; what is being checked is the arithmetic inside each row, which the condition moves together and therefore cannot explain.
| Model | Capacity | Power | Printed COP | Capacity divided by power | Verdict |
|---|---|---|---|---|---|
| KSG165V1UMT | 4,285 W | 1,440 W | 2.98 | 2.9757 | passes |
| KSG185V1UKU | 4,775 W | 1,605 W | 2.98 | 2.9751 | passes |
| KSG230V1UKU | 5,945 W | 1,980 W | 3.00 | 3.0025 | passes |
| KSG165S1VMT | 5,185 W | 1,200 W | 4.32 | 4.3208 | passes |
| KSG210S1VMP | 6,610 W | 1,495 W | 4.42 | 4.4214 | passes |
| KSG230N1VMT | 8,525 W | 1,930 W | 4.42 | 4.4171 | passes |
| KSG290V1VMU | 9,055 W | 2,050 W | 4.34 | 4.4171 | does not pass |
The failing row is KSG290V1VMU on printed page 13, which prints 4.34 where its own capacity and power divide to 4.4171. The margin is large enough that rounding cannot explain it: 4.4171 rounds to 4.42, and 4.42 is exactly what two other rows at the same ratio print on the same spread. The most economical explanation is a transposition in the coefficient column, and the practical rule is to use 4.42 if that row is ever specified, or better, to quote the capacity and the power and let the buyer divide.
The British thermal unit column does not have the same problem. Across all twenty rows the implied factor is between 3.41190 and 3.41205, which is the standard conversion to five decimal places. This family has no conversion defect, which is worth recording because other GMCC families in this catalogue do. A reader who has been burned by a rounding shortcut elsewhere should not expect one here.
The audit also settles a question that a reader might reasonably ask about this model's own row. Nothing about KSG165V1UMT is anomalous. It passes on the coefficient, it passes on the British thermal unit conversion, its displacement sits inside the family's code tolerance, and its two ratios are in the middle of the band its condition defines. The interesting findings in this article are about the neighbours, not about the row.
What the shop pages print for this family
Seven product pages in this shop carry a KSG string, and a buyer comparing this model will usually land on one of them first. None of the seven is this model. Reading each page against the catalogue row for the same code is a short exercise, and it produces three different outcomes: one page reproduces its row to the watt, three pages carry a string the catalogue does not print at all, and one page prints a pair of numbers that no row in the family supports.
| Shop page | Displacement | Capacity | Power input | Implied coefficient | Catalogue row for the same code |
|---|---|---|---|---|---|
| KSG210S1VMP | 21.1 cm3/rev | 6,610 W | 1,495 W | 4.42 | identical on all three numbers |
| KSG280V1VMU | 28.0 cm3/rev | 8,630 W | 2,045 W | 4.22 | 8,620 W on 2,060 W, printed 4.18 |
| KSG230V1UKU | 23.0 cm3/rev | 7,765 W | 1,654 W | 4.69 | 5,945 W on 1,980 W, printed 3.00 |
| KSG289V1VMU | 28.9 cm3/rev | 8,920 W | 2,050 W | 4.35 | filed as KSG290V1VMU, 9,055 W on 2,050 W, printed 4.34 |
| KSG186V1VKU | 18.6 cm3/rev | 4,800 W | 1,655 W | 2.90 | no row at this string; the catalogue prints KSG185V1UKU at 18.5 |
| KSG196V1VKU | 19.6 cm3/rev | 5,065 W | 1,750 W | 2.89 | no row at 19.6 under a V supply; the catalogue prints KSG195S1VKU under an S supply |
| KSG250V1VMT | 25.0 cm3/rev | 7,710 W | 1,795 W | 4.30 | no row at a V supply; the catalogue prints KSG250S1VMU at 25.0 |
One page in seven is exact, and it is worth saying so first because it rules out a systematic fault. The 21.1 cm3/rev page prints 21.1 cm3/rev, 6,610 W, 1,495 W and 4.42; the catalogue prints the same four values for the same string on printed page 15, in the GX block. Where the shop transcribed a printed row, the transcription is clean. The problem pages are the ones where the shop did something else to the row.
The 22.9 cm3/rev page is the one that does damage. Its capacity sits 30.6 per cent above the ARI row printed for the same code and 9.2 per cent above the GX row printed at the same displacement, while its power input sits one watt below the GX row. Divide the two and the page implies a coefficient of 4.69. That is above every coefficient printed anywhere in the twenty row family, where the highest printed value is 4.45 on the 17.5 cm3/rev row and no row in the document prints above that. A ratio above the whole family's range is not a rounding difference. It means the capacity and the power on that page were not measured together, and a buyer who quotes 7,765 W from it will be quoting a number the manufacturer does not print at all.
The 289 string is a smaller fault of the same kind. The catalogue files the 28.9 cm3/rev row as KSG290V1VMU and prints 9,055 W on 2,050 W. The shop page is titled KSG289V1VMU, prints 28.9 cm3/rev, which agrees with the row it copies, and prints 8,920 W on 2,050 W, which does not. The displacement field identifies the row; the model string contradicts it by one digit.
Three of the seven strings have no catalogue row behind them: 18.6, 19.6 and 25.0 cm3/rev at a V supply. The catalogue covers 18.5 as KSG185V1UKU and 25.0 as KSG250S1VMU, and prints nothing at 19.6 under a V supply, only KSG195S1VKU at 19.6 under an S supply. None of the three carries a number outside the family's printed bands, so the risk on those pages is a model string a buyer cannot match to a datasheet rather than a rating that misleads.
There is no product page for KSG165V1UMT in this shop at all. The only page carrying the string is the article you are reading, and the group page at the foot of this article lists 214 products with no KSG165 entry among them. A buyer for this barrel therefore has a catalogue row and seven sibling pages, and the seven paragraphs above are the reason the row should be the authority and the shop's arithmetic should be treated as a lead rather than a measurement.
Where KSG165V1UMT fits: cooling loads, not freezer loads
The request described this string as a rotary air conditioner compressor, and the catalogue supports that description on its own terms. The naming page carries an application field whose default entry is compressors for air conditioning, with separate markers for heat pumps, freezing and cold storage, heating and cabinet air conditioning. The KSG165V1UMT row carries no marker, so under the manufacturer's own table it is a default air conditioning compressor. Three consequences follow, and each one is a specification decision rather than a description.
The first is the size of the load. The printed 4,285 W is a cooling capacity at the ARI condition, and in the unit a North American buyer will reach for it is about 1.22 tons of refrigeration, from 4,285 divided by 3,516.85. The same row as an energy efficiency ratio is 10.15 Btu per watt hour, from the printed 14,620 Btu/h divided by the printed 1,440 W; the printed coefficient multiplied by 3.412 gives 10.17, a gap of one part in six hundred that comes from rounding on the row. Both numbers are derived rather than printed, and both inherit the condition.
The second consequence is the swept volume, which the row gives only in cm3/rev. At the printed supply, 16.7 cm3/rev at 3,000 rev/min comes to 50,100 cm3/min. That figure is what a system designer needs to size suction line velocity and to compare this row against a scroll of the same nominal capacity, and it is not printed anywhere on the row.
The third consequence is what the machine is not. There is no freezing or cold storage marker on this row, and the ARI band it is printed in, 256.6 W per cm3/rev, is about 20 per cent below the GX band the same hardware carries elsewhere in the catalogue. A buyer who reads 4,285 W and assumes a cold room has the condition backwards, and will size a unit that is under capacity at freezer temperatures. If the load is a freezer, a cold room or a transport body, the correct families in this catalogue are the ones marked for freezing, and the rotary compressor range is where the shop groups them.
| Load | Why the row fits or does not | What to check before ordering |
|---|---|---|
| Wall mounted split in the 3.5 to 4.5 kW class | 4,285 W at ARI on a single phase supply | charge and pipe run |
| Multi split outdoor unit | 220/240 V single phase is a domestic supply | number of indoor units |
| Ducted light commercial up to about 5 kW | 310 mm height fits a shallow plenum | external static pressure |
| Small packaged or rooftop unit | run capacitor printed as 40/400 | ambient derating |
| Freezer, cold room, transport body | no freezing marker, and the ARI band is the lowest in the family | a row marked for freezing |
| Designated heat pump | no heat pump marker on the row | ask GMCC whether a marked build exists |
| Three phase supply | the header prints single phase only | a 3ph family, or a scroll of the same duty |
Selection advantages, and the fields the row does not print
The case for this row is narrow and it is real, and the narrowness is the point. Five things on the row are decisions already made by the manufacturer and settled for the builder.
| Advantage | What on the row establishes it |
|---|---|
| No three phase supply to provide | header prints 1ph at 50 Hz and 220/240 V |
| One chassis envelope across the SG group | 310 mm height on all three rows of the group |
| Capacity steps with no efficiency penalty | 256.6, 258.1 and 259.6 W per cm3 across 16.7 to 22.9 |
| Run capacitor specified before purchase | 40/400 printed in the row |
| In production rather than announced | no triangle in the last column |
The efficiency point deserves one more line, because it is where buyers usually guess wrong. Moving from 16.7 to 22.9 cm3/rev in this group buys 39 per cent more cooling for 37.5 per cent more electricity, and the coefficient moves from 2.98 to 3.00. There is no efficiency reward for buying the small barrel and no efficiency penalty for buying the large one. The small row buys envelope, and only envelope.
The other side of that is a short list of fields the row does not carry, and a buyer who needs them has to ask rather than derive.
| Not printed on the row | Consequence for the builder | Where it has to come from |
|---|---|---|
| Sound pressure or sound power | acoustic treatment cannot be sized | the supplier, in writing |
| Oil type and oil charge | the system cannot be pre charged | the supplier, in writing |
| Net weight | freight and pallet planning | the supplier, in writing |
| Refrigerant mass flow | expansion device cannot be sized | derived from capacity and enthalpy |
| A three phase build of this string | a 3ph tender cannot use it as printed | a different family in the same catalogue |
| A 60 Hz rating for this string | an export build is not covered by these numbers | the 60 Hz blocks print their own rows |
The practical rule follows from the two tables. Specify the model by its full string, with the refrigerant and the supply spelled out and the condition named, as in GMCC KSG165V1UMT, R32, single phase 220 to 240 V 50 Hz, rated 4,285 W at the ARI condition. Then ask for the oil charge, the sound data and the mass weight in the same enquiry, because none of the three is on the document the rating came from. Anyone who needs to check which families the shop actually stocks, rather than which the catalogue rates, can read the product index and compare it against the seven pages above.
Standards, refrigerant designation and the documents behind the numbers
Four documents outside the catalogue matter to this row, and each one answers a different question.
| Document | What it settles for this row |
|---|---|
| IEC 60335-2-34, 2024 edition | whether the compressor itself is inside a safety standard, and at what voltage |
| IEC 60335-2-40, 2024 edition | the appliance the compressor ends up in, and the duties that apply there |
| German Environment Agency GWP table | what R32 is worth as a greenhouse gas |
| IEA report on cooling | why a 4,285 W single phase barrel is a commercial object in the first place |
The compressor part is the one that decides the voltage question. IEC 60335-2-34:2024 deals with the safety of sealed hermetic and semi-hermetic motor-compressors, and it applies to motor-compressors tested separately under the most severe conditions that can be expected in normal use, their rated voltage being not more than 250 V for single-phase motor-compressors and 600 V for multi-phase, 600 V direct-current motor-compressors. The 2024 edition names one of its changes as the addition of the rating up to 600 V in the scope. The supply printed for this row, 220 to 240 V single phase, sits inside the single phase limit with 10 V to spare at the top of the band.
The appliance part is the one buyers forget. IEC 60335-2-40:2024 carries the title Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers, and it deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners incorporating motor-compressors, as well as hydronic fan coil units and dehumidifiers. A rotary compressor sold into a split system is therefore governed twice: once as a sealed component and once as part of the assembly, and the second set of duties belongs to whoever builds the unit rather than to the barrel.
On the refrigerant, R32 is difluoromethane, and the agency table gives its hundred year global warming potential as 675 under the Fourth Assessment Report, 677 under the Fifth, and 675 again in the column that tracks the European regulation. The 675 figure is the one a European buyer will apply, because it is the value carried in the regulation column of the same table. The catalogue prints R32 in the block header rather than a blend designation, so nothing in this article depends on a composition table.
The commercial context is the fourth document. The IEA reports that using air conditioners and electric fans to stay cool accounts for nearly 20 per cent of the total electricity used in buildings around the world today, that by 2050 around two thirds of the world's households could have an air conditioner, and that cooling is the fastest growing use of energy in buildings. A compressor in the 4 kW class on a domestic single phase supply is the component those numbers are made of.
Two references a careful reader might expect are deliberately absent. The ASHRAE refrigerant designation pages and a widely cited lower-GWP case study compilation both declined automated requests at the time of writing, so neither is cited here. Everything above was read directly from the page or the file named, and the manufacturer's own product index and its download centre, where the catalogue used throughout this article is published, are both open for a reader who wants to check the chain: GMCC product range and GMCC download centre.
Questions buyers ask about KSG165V1UMT
Is KSG165V1UMT an R32 compressor or an R404A compressor?
It is R32. Two independent places on the same document say so. The naming page lists K as the refrigerant code for R32 and R410A, and lists S as the code for R404A, as separate entries in the same table; the block header above the row prints R32 over the supply. A string beginning with KSG cannot be an R404A machine under the manufacturer's own rules, whatever a third party listing puts in that field.
Which numbers should I quote for KSG165V1UMT?
Quote the row rather than a listing: 16.7 cm3/rev, 4,285 W of cooling and 14,620 Btu/h, 1,440 W of power input, a coefficient of 2.98, a 40/400 run capacitor, 310 mm height and two pipes at 9.8 mm and 16.2 mm, on R32 at single phase 220 to 240 V 50 Hz, at the ARI condition, in production. If a quotation has to carry one sentence, the sentence is 4,285 W on 1,440 W at ARI on R32.
Why does the shop page for KSG230V1UKU print 7,765 W when the catalogue prints 5,945 W?
The two figures are not the same measurement. The catalogue row prints 5,945 W on 1,980 W at the ARI condition for that code. The shop page prints 7,765 W on 1,654 W, which is 30.6 per cent more capacity on 16.5 per cent less power, and implies a coefficient of 4.69 against a family maximum of 4.45. No printed row supports that pair, so the catalogue figure is the one to quote and the shop page should be treated as a lead on availability rather than a rating.
Should I specify KSG165V1UMT or KSG165S1VMT?
They are different builds on different benches, not two spellings of one product. The V string is single phase 220/240 V, printed at ARI, 4,285 W on 1,440 W for 2.98. The S string is single phase 230 V, printed at GX, 5,185 W on 1,200 W for 4.32. Capacity differs by 21 per cent and the printed coefficient by 45 per cent, while the capacitor and the height are identical. Specify the string and the condition together, and never move a number between them.
Is KSG165V1UMT suitable for a cold room or a freezer?
No, and the document says so by omission. The naming page carries an application field with separate markers for heat pumps, freezing and cold storage, heating and cabinet air conditioning; this row carries none of them, which makes it a default air conditioning compressor. The band it is printed in, 256.6 W per cm3/rev, is the lowest of the four bands in the family, which is what a mild condition looks like. A freezer enquiry needs a row marked for freezing.
Can KSG165V1UMT be run at 60 Hz on the strength of these numbers?
Not on the strength of this row. The catalogue prints its 60 Hz builds as separate rows under an N supply code at 208 to 230 V, and those rows carry their own capacity, power and coefficient. Scaling a 50 Hz rating by frequency is a guess dressed as arithmetic, because the swept volume scales with speed while the volumetric and isentropic efficiencies do not. Ask for the 60 Hz row, or for a manufacturer statement, before quoting an export build.
What does the printed coefficient of 2.98 mean in efficiency ratio terms?
It is 2.98 W of cooling per watt of electricity, and multiplying by 3.412 gives 10.17 Btu per watt hour. Dividing the printed 14,620 Btu/h by the printed 1,440 W gives 10.15, and the two differ in the third significant figure because the row is rounded. Both are ARI condition values, so neither can be compared against a European or a GX condition rating without restating the condition.
Is there a product page or a price for KSG165V1UMT in this shop?
There is no product page for this string. The only page in the shop that carries it is the article you are reading, and the group page the button at the foot of this article points to lists 214 products with no KSG165 entry among them. The shop's news index and its write-up of a related ASQ280Y1UMP rotary are the nearest pages it keeps on rotary models, and neither carries this string either. A price therefore has to be requested rather than read.
What should I ask the supplier that the datasheet does not answer?
Four things, all missing from the row: the oil type and oil charge, the sound pressure or sound power figure, the net weight, and the refrigerant mass flow. Add a fifth if the tender is not domestic: whether a three phase build of this string exists, because the header prints single phase only. Asking for those five in the first enquiry costs one message and saves a redesign, since none of them can be derived from the printed capacity and power with any confidence.
Sources
Every figure in this article traces to one of the rows below. Tier 1 is the manufacturer's own document, Tier 2 is this shop's own pages, Tier 3 is a standards body, agency or intergovernmental body, and Tier 4 is reserved for material that was checked and rejected.
| No. | Source | Tier | What it supports |
|---|---|---|---|
| S508 | GMCC Rotary Compressor Product Catalog, 2024 edition. File manual2024.pdf, 2,990,900 bytes, md5 5c58f3bf5681501f481fd8396febc207, 20 PDF pages | 1 | the KSG165V1UMT row, all twenty KSG rows, every printed value and every arithmetic check |
| S509 | The same document, printed pages 5 and 6 | 1 | refrigerant letters, power source codes, displacement rule, application field |
| S510 | The same document, the triangle legend printed on every page carrying a mark | 1 | in production status for the row |
| S511 | qishanrcompressor.com/products/gmcc-gmcc-compressor-ksg210s1vmp.html | 2 | shop figures 21.1 cm3/rev, 6,610 W, 1,495 W, 347,780 bytes |
| S512 | qishanrcompressor.com/products/gmcc-compressor-ksg230v1uku.html | 2 | shop figures 23.0 cm3/rev, 7,765 W, 1,654 W, 347,526 bytes |
| S513 | qishanrcompressor.com/products/gmcc-compressor-ksg250v1vmt.html | 2 | shop figures 25.0 cm3/rev, 7,710 W, 1,795 W, 348,107 bytes |
| S514 | qishanrcompressor.com/products/r32-gmcc-compressor-ksg280v1vmu.html | 2 | shop figures 28.0 cm3/rev, 8,630 W, 2,045 W, 347,748 bytes |
| S515 | qishanrcompressor.com/products/gmcc-compressor-ksg289v1vmu.html | 2 | shop figures 28.9 cm3/rev, 8,920 W, 2,050 W, 347,859 bytes |
| S516 | qishanrcompressor.com/products/gmcc-compressor-ksg186v1vku.html | 2 | shop figures 18.6 cm3/rev, 4,800 W, 1,655 W, 348,089 bytes |
| S517 | qishanrcompressor.com/products/gmcc-compressor-ksg196v1vku.html | 2 | shop figures 19.6 cm3/rev, 5,065 W, 1,750 W, 348,099 bytes |
| S518 | webstore.iec.ch/en/publication/80533, IEC 60335-2-34:2024 | 3 | scope of the motor-compressor standard and its voltage limits |
| S519 | webstore.iec.ch/en/publication/83993, IEC 60335-2-40:2024 | 3 | title and appliance scope of the heat pump and air conditioner standard |
| S520 | German Environment Agency GWP table PDF, 254,775 bytes, md5 38043bd157abc8efba18704d48479d99 | 3 | HFC-32 GWP of 675, 677 and 675 in the three columns |
| S521 | iea.org/reports/the-future-of-cooling | 3 | the 20 per cent share of building electricity and the 2050 household projection |
| S522 | gmcc-welling.com/en/product | 1 | the manufacturer's product index |
| S523 | gmcc-welling.com/en/solution/download-list | 1 | the manufacturer's download centre, where the catalogue is published |
| S524 | qishanrcompressor.com/gmcc-rotary-compressor.html | 2 | the button target, 342,103 bytes, 214 products, no KSG165 entry |
| S525 | qishanrcompressor.com/ksg165v1umt-gmcc-rotary-air-conditioner-compressor.html | 2 | the only shop page carrying the string, 837,560 bytes |
| S526 | qishanrcompressor.com/news.html | 2 | the news index, 1,147,304 bytes |
| S527 | qishanrcompressor.com/blog-5713226366761991.html | 2 | the related rotary write-up, 317,884 bytes |
| S528 | qishanrcompressor.com/rotary-compressor.html | 2 | the rotary range page, 343,143 bytes |
| S529 | qishanrcompressor.com/gmcc-scroll-compressor.html | 2 | the scroll range page, 343,448 bytes |
| S530 | qishanrcompressor.com/en/product.html | 2 | the product index, 364,993 bytes |
Two sources were checked and are not used. The ASHRAE refrigerant designation pages returned a 403 refusal on every attempt, and the Climate and Clean Air Coalition case study compilation returned a 403 as well. Neither is cited anywhere in the text, and no claim in this article depends on either.
GMCC SAVC060D11ULKC scroll compressor