GMCC KSN78V11VDZ Rotary Compressor: The 2024 Catalogue Prints a 7.8 cm3 Air Conditioning Build, Not a Refrigeration Compressor
Key facts at a glance
| Field | Value | Where it comes from |
|---|---|---|
| String as supplied | KSN78V11VDZ | Buyer request, no prefix added |
| Row printed in the 2024 edition | KSN78V11VDZ | Page 13, SN group, fixed-speed block |
| Refrigerant | R32 | Block heading on page 13 |
| Supply, block level | 1 phase, 50 Hz, 220/240 V | Block heading on page 13 |
| Test condition | GX | Block heading on page 13 |
| Displacement | 7.8 cm3/rev | Row |
| Cooling capacity | 2350 W / 8018 Btu/h | Row |
| Input | 600 W | Row |
| Coefficient of performance | 3.92 W/W | Row |
| Run capacitor | 25/370 | Row |
| Body height | 250 mm | Row |
| Suction / discharge | 8.1 / 9.8 mm | Row |
| Development flag | none | Row (no triangle mark) |
| Application field in the naming rule | blank, which the rule defines as air conditioning | Naming page, printed 05 |
| Architecture | rotary | Catalogue title and the block's own family grouping |
The last row of that table is the one to keep in view. Everything above it is printed; the word refrigeration is not among the printed fields.
Why does the label say refrigeration when the manual says air conditioning?
Three independent places in the document point the same way, and one place points the other way, and that one place is the channel.
The block heading is explicit. Page 13 opens with the Chinese line for a green-refrigerant air conditioning compressor and its English rendering GREEN REFRIGERANT COMPRESSOR underneath. The rows below it are grouped by family letters SK, SN, SM, GF, SG, SQ, TG, TQ. Nothing on the page speaks about freezing or cold storage.
The naming rule has a dedicated field for exactly that distinction. Its application field reads: blank means compressors for air conditioning; R means compressors for heat pumps; L means compressors for freezing and cold storage; E means compressors for heating; G means compressor for cabinet AC. The string carries no L. It cannot claim the cold-storage field, because it does not fill that field.
The refrigerant letter agrees. The naming rule maps K to R32 and R410A, the two mainstream air-conditioning working fluids. A freezing application in this catalogue appears under different letters and different blocks, and those blocks are printed elsewhere in the same edition.
What contradicts all three is the usage line that the supplier pages print: AC, drier, refrigeration, chiller, etc. That exact string appears on every compressor page on the site, character for character, including pages for builds that no catalogue would place in a freezer. It is a site template, not a model-level statement, and it should not be read as an application claim for this or any other string.
The label is therefore half right. Rotary is documented: the whole edition is a rotary catalogue, and this string sits inside the SN family that the edition prints as rotary. Refrigeration is not documented anywhere in the edition for this string. A buyer who needs a freezing compressor should be routed to a block that prints the L field or to a dedicated low-temperature family, not to this row.
What does the row print, and what closes?
The row reads, in the page order of the 2024 edition:
| Displacement | Capacity | Capacity | Input | COP | Capacitor | Height | Suction | Discharge |
|---|---|---|---|---|---|---|---|---|
| 7.8 cm3/rev | 2350 W | 8018 Btu/h | 600 W | 3.92 | 25/370 | 250 mm | 8.1 mm | 9.8 mm |
Three checks close arithmetically, and they are worth doing because the printed figures are rounded in different directions across the edition.
The coefficient of performance is capacity over input: 2350 divided by 600 is 3.9167, printed 3.92. The British thermal figure is the watt figure times the standard factor: 2350 times 3.412 is 8018.2, printed 8018. The swept volume per second follows from the displacement and the block frequency: 7.8 cm3 per revolution at 50 Hz is 390 cm3 per second, and 600 W spread over that volume is 1.538 W per cm3 per second.
Two of those three closures appear across the whole ladder and two do not, which is itself useful. The capacity-to-input ratio is printed to two decimals everywhere, and one row in the ladder rounds in the unusual direction, described below. The Btu column is not a pure product on every row either, so a buyer who needs exact Btu should compute it rather than trust the column.
The capacitor value is the field that separates this block from the inverter blocks in the same edition. A fixed-speed build needs a run capacitor, and the row prints one: 25 microfarads at 370 VAC. On the twin-cylinder inverter pages the same column prints a dash, which means the drive replaces the capacitor, not that the data is missing. Reading the dash as absent data is a common error and it changes how a system is specified.
What does the GX condition cover, and what does it leave out?
GX is the test condition named in the block header on page 13. It is a single-point rating, and the edition uses it consistently for the fixed-speed half of the SN family. That has three consequences a designer should hold onto.
First, 2350 W belongs to GX at 1 phase, 50 Hz, 220/240 V. It is not a seasonal figure, not an annual figure and not a heating figure. Where the same edition prints SEER60 blocks, the header names a seasonal metric instead, and those numbers do not travel between blocks.
Second, the row prints no heating capacity and no heating coefficient of performance. The supply and condition are cooling-side. A heat pump built around this compressor needs a heating rating that this page does not contain, and that rating has to come from the manufacturer in writing rather than from arithmetic on 2350 W.
Third, the row prints no mass, no oil charge, no oil grade, no running current, no speed, no sound power or pressure level, no locked-rotor current and no ingress protection. Those are real design inputs, they are absent, and any figure a buyer sees for them did not come from this document.
Where does 7.8 sit in the SN ladder?
The fixed-speed SN group on page 13 runs from 4.0 to 9.8 cm3 in eight rows. All eight share the same supply and the same GX condition, which is what makes them comparable with each other and with nothing else.
| Row | Displacement | Capacity | Input | COP | Capacitor | Height | Per cm3 | Per cm3/s |
|---|---|---|---|---|---|---|---|---|
| KSN40V11VAZ3 | 4.0 | 1150 W | 298 W | 3.85 | 10/370 | 230 | 287.5 | 1.490 |
| KSN54V11VZZ3 | 5.4 | 1630 W | 410 W | 3.98 | 15/370 | 230 | 301.9 | 1.519 |
| KSN68V11VBZ | 6.8 | 2020 W | 518 W | 3.90 | 25/370 | 250 | 297.1 | 1.524 |
| KSN78V11VDZ | 7.8 | 2350 W | 600 W | 3.92 | 25/370 | 250 | 301.3 | 1.538 |
| KSN86V11VDZ | 8.6 | 2550 W | 658 W | 3.88 | 25/370 | 250 | 296.5 | 1.530 |
| KSN89V11VEZ3 | 8.9 | 2675 W | 655 W | 4.08 | 25/400 | 280 | 300.6 | 1.472 |
| KSN92V11VEZ3 | 9.2 | 2780 W | 688 W | 4.04 | 25/400 | 280 | 302.2 | 1.496 |
| KSN98V11VEZ3 | 9.8 | 3020 W | 722 W | 4.18 | 25/400 | 280 | 308.2 | 1.473 |
The two derived columns are ours, computed as capacity divided by displacement and input divided by swept volume at 50 Hz. They are shown because they expose a pattern the raw columns hide.
Capacity per cubic centimetre is not monotonic. It rises to 301.9 at 5.4, falls to 297.1 at 6.8, returns to 301.3 at 7.8, falls again to 296.5 at 8.6, and only then climbs to the top of the range at 9.8. Two mechanical steps show up in the printed fields and explain most of the sawtooth: the capacitor jumps from 15/370 to 25/370 between 5.4 and 6.8, and again from 25/370 to 25/400 between 8.6 and 8.9, where the body also grows from 250 mm to 280 mm. The 7.8 row sits on the good side of the first step.
Input per swept volume tells the same story in reverse. The three smallest rows run between 1.490 and 1.538; the three largest, all flagged as under development, come in at 1.472 to 1.496. The 7.8 row is the most input-hungry of the released builds at 1.538, which is the price of the small body: same displacement, less gas moved per revolution, more work per cubic centimetre.
Is 7.8 the efficient choice or just the smaller one?
Both, and the order matters. Two step comparisons settle it.
Stepping down from 7.8 to 6.8 costs 16.3 percent of capacity, since 2020 divided by 2350 is 0.860, and saves 15.8 percent of input, since 518 divided by 600 is 0.863. The printed coefficient moves from 3.92 to 3.90, a loss of half a percent. That is a fair trade for a smaller machine: capacity and input fall almost together.
Stepping up from 7.8 to 8.6 buys 8.5 percent more capacity, since 2550 divided by 2350 is 1.085, for 9.7 percent more input, since 658 divided by 600 is 1.097. The printed coefficient falls from 3.92 to 3.88, about one percent worse. That is a losing trade on efficiency, and it is the only upward step in the released half of the ladder that behaves this way.
So the 7.8 row is the top of the efficient stretch, not the top of the range. Above it, the released builds get bigger and slightly worse per watt until the development tier takes over at 8.9. Below it, the builds get smaller with almost no efficiency penalty until 5.4, which prints the best coefficient of the entire released half at 3.98. A buyer whose load sits between 2020 W and 2350 W should read 7.8 as the default and 6.8 as the de-rated alternative, and should not step to 8.6 for margin without accepting the efficiency loss.
Three cautions come with that reading. The coefficients are printed to two decimals, so a difference of 0.02 to 0.04 is close to rounding territory and should not be treated as a ranking. The 8.9, 9.2 and 9.8 rows carry the under-development triangle, so their better numbers are not a purchasing option today. And every figure in this section is at GX, 50 Hz, 220/240 V: change the supply and the whole ladder shifts, as the next section shows.
Four builds at 7.8 in the same edition
The same displacement appears four times in the 2024 edition, in four different blocks, under three different supply specifications and two different test conditions. They are not alternatives to each other; they are different machines that happen to share a number.
| String | Supply | Condition | Capacity | Input | COP | Capacitor | Winding | Page |
|---|---|---|---|---|---|---|---|---|
| KSN78V11VDZ | 1 phase, 50 Hz, 220/240 V | GX | 2350 W | 600 W | 3.92 | 25/370 | copper | 13 |
| KSN78E11VBZC1 | 1 phase, 60 Hz, 115 V | GX | 2875 W | 685 W | 4.20 | 50/250 | copper | 11 |
| KSN78E13UZDS1 | 1 phase, 60 Hz, 115 V | ARI | 2345 W | 855 W | 2.74 | 50/250 | copper | 11 |
| KSN78E01VAZC1 | 1 phase, 60 Hz, 115 V | GX | 2930 W | 805 W | 3.64 | 60/250 | aluminium | 17 |
The spread in capacity is 585 W, from 2345 to 2930, on identical displacement. None of that spread is available to a buyer choosing between versions of one machine, because the supply and the condition differ.
Most of it is frequency. A 60 Hz supply turns the same geometry twenty percent faster than 50 Hz, and 2350 W lifted by that factor is 2820 W. The 115 V builds print 2875 W and 2930 W, which is 2.0 and 3.9 percent above that estimate. The residual is consistent with the different capacitor and, on the aluminium-winding build, a different conductor. Treat the frequency term as an inference from the printed supplies, not as a statement the catalogue makes.
The ARI row is the one that should stop a careless reader. It prints the lowest capacity of the four, 2345 W, with the highest input, 855 W, and a coefficient of 2.74. Read next to the GX row at the same frequency it looks like a bad machine. It is not: ARI is a different rating condition, and the coefficient that belongs to it is simply a different number for the same hardware. Comparing a coefficient across conditions is the single most common error in this family.
What do the supplier pages print?
Four pages on the supplier site sit close enough to this displacement to be read as neighbours. Two of them are fixed-speed and two are inverter builds, and the difference shows up in a field that matters.
| Page | Displacement | Input | Capacity | COP | Voltage field |
|---|---|---|---|---|---|
| KSM89V1VDZ | 8.9 cm3/rev | 635 W | 2665 W | 4.20 | 220-240 V, 50 HZ, 1PH |
| KSM125V1VFT | 12.5 cm3/rev | 900 W | 3810 W | 4.23 | 220-240 V, 50 HZ, 1PH |
| KSN98D22UFZ | 9.7 cm3/rev | 778 W | 3050 W | 3.92 | DC INVERTER |
| KSN108D22UFZ | 10.8 cm3/rev | 881 W | 3455 W | 3.92 | DC INVERTER |
The fixed-speed pages carry a real supply; neither of them states a test condition. The page for KSM89V1VDZ states 220-240 V, 50 HZ, 1PH in the voltage field, and KSM125V1VFT states the same. That is exactly the kind of statement a system designer needs and it is consistent with the block headers in the edition. The inverter pages carry the drive name in the voltage field instead: DC INVERTER, twice, on two different models. A reader who goes to a D-series page looking for a voltage will not find one. This article therefore does not quote a voltage for any inverter build, and does quote one for this row's block, because the block header prints it.
The displacement field has its own defect. KSN98D22UFZ prints 9.7 cm3 while its own model code says 98 and the edition prints 9.8 for that step. The page's other three values, 3050 W, 778 W and 3.92, are internally consistent and close to, but not equal to, the edition's 9.8 build at 3070 W, 784 W and 3.92. KSN108D22UFZ prints 10.8 cm3, 3455 W and 881 W where the edition's only 10.8 row prints 3410 W, 865 W and 3.94. Neither page is safe to quote as the edition's row.
The similar fixed-speed pages also disagree with the edition on strings that differ by one character. KSM89V05VDZ3 in the edition prints 2690 W, 672 W and 4.02 in a 290 mm body; the page for KSM89V1VDZ prints 2665 W, 635 W and 4.20 in a body whose height the page does not state. Those are different strings and the difference is legitimate, but it means the two cannot be averaged, and a buyer who quotes the page's 4.20 while ordering the edition's V05 build is quoting the wrong document.
There is no page for this article's string. A site index scan returns no result for KSN78, and the two obvious candidate URLs both return 404. Everything in this article therefore reads from the edition, and the supplier pages appear only as neighbours that demonstrate the field defects.
How should a buyer specify this build?
Six steps, in the order that avoids the two traps above.
1. Order by the full string. KSN78V11VDZ is the row. Not the 7.8 displacement, which four different builds share, and not the SN family, which spans 4.0 to 9.8.
2. Fix the supply before quoting a capacity. The 2350 W figure belongs to 1 phase, 50 Hz, 220/240 V at GX. Any other supply moves the number, and the edition prints three other supplies for the same displacement.
3. Ask for the heating rating in writing if the machine is going into a heat pump. The row does not print one, and 2350 W is a cooling figure.
4. Size the capacitor and the contactor from the printed 25/370 and from your own circuit design. The dash on inverter rows is not comparable; this row is fixed-speed and does need a run capacitor.
5. Check the piping against 8.1 mm suction and 9.8 mm discharge. These are the same across the whole released SN ladder, so a design written for 6.8 or 8.6 transfers without a pipe change, which is a genuine advantage of staying inside this group.
6. Confirm the application in writing if you intend to use the machine for anything colder than comfort cooling. The block heading, the naming rule and the refrigerant letter all describe air conditioning, and the usage line that mentions refrigeration is a site template.
Where can this row be checked?
Three independent checks are available to a buyer who wants to verify the figures rather than accept them.
The edition itself. The row sits on page 13 of the 2024 catalogue, in the fixed-speed SN group, under the header that names 1 phase, 50 Hz, 220/240 V and the GX condition. The file is a 20-page PDF of 2,990,900 bytes with an MD5 of 5c58f3bf5681501f481fd8396febc207; a distributor-hosted copy of the 2024 manual can be downloaded and compared byte for byte. Two manufacturer entries are also useful: the manufacturer's product centre for the current range, and the downloads page on the manufacturer site as the official route to the file.
The arithmetic. Every closure in this article is reproducible with a calculator: 2350 over 600, 2350 times 3.412, 7.8 times 50, and 600 divided by that product. If a revised edition changes the row, the closures will change with it and the difference will show.
The neighbouring pages. The site carries pages on both sides of this build, such as KSM125V1VFT in the larger fixed-speed half and KSN98D22UFZ in the inverter half. They confirm the field pattern even where their own numbers drift from the edition. The site's GMCC rotary compressor range page lists the family as a whole, and the GMCC brand index groups every range the supplier carries.
Which standards and approvals frame the purchase?
Nothing in the row prints a certificate, a safety mark or a compliance statement, and no claim of certification should be inferred from this article. Three external references do frame the compliance work a buyer will have to do.
For the electrical safety of the component, IEC 60335-2-34, which is the part of the household appliance series written for motor-compressors, is the reference most often named in procurement documents for hermetic compressors. Holding a copy of the standard is not evidence that a specific build was tested to it.
For the refrigerant, R32 is a fluorinated gas with a global warming potential well below the R410A it displaces, but it is still a fluorinated gas. A machine charged with R32 and placed on the European market falls under Regulation (EU) 2024/573, the framework that governs fluorinated gases, and the obligations attach to the charge and to the operator rather than to the compressor's catalogue page.
For the reason the industry is moving, the IEA's The Future of Cooling remains the most cited framing of how cooling demand grows with income and temperature. It is context for a selection decision, not evidence about a specific compressor.
The wider rotary compressor category page on this site groups the family for readers who want to see how a 7.8 cm3 build compares with the rest of the rotary range, and the GMCC scroll line is where a buyer should look only after accepting that scroll numbers do not transfer to a rotary row. An R410A example on the blog side applies the same field-by-field method to a different refrigerant.
Frequently asked questions
Is KSN78V11VDZ a refrigeration compressor?
The string is in the 2024 edition, in a block headed green refrigerant air conditioning compressor, under the blank application field that the naming rule defines as air conditioning, working with R32. The word refrigeration appears only in a site-wide usage template that says AC, drier, refrigeration, chiller, etc. on every page. The documented application is air conditioning.
What does 78 mean in the model number?
It is the displacement field multiplied by ten: 7.8 cm3 per revolution. The row confirms it, and the same convention holds across the whole SN ladder from 40 to 98.
Can I use 2350 W at a different supply voltage?
No. The figure belongs to 1 phase, 50 Hz, 220/240 V at the GX condition, which is the block header on page 13. The edition prints the same displacement at 60 Hz and 115 V with capacities between 2345 W and 2930 W, so the number moves with the supply.
What does GX mean in this catalogue?
It is the test condition named in the block header, and it is used for the fixed-speed half of the SN family. It is a single-point rating, not a seasonal one; where the edition uses a seasonal metric the header says so instead.
What capacitor does this build need?
The row prints 25/370, meaning 25 microfarads at 370 VAC. That is a run capacitor for a fixed-speed machine. The twin-cylinder inverter blocks print a dash in the same column because the drive replaces it, not because the value is unknown.
Why do four different strings print 7.8 cm3?
Because displacement is geometry and the edition groups builds by supply and test condition as well as by size. The four differ in frequency, winding and rating condition, so their capacities run from 2345 W to 2930 W on the same swept volume.
Is 8.6 cm3 a better buy than 7.8?
It buys 8.5 percent more capacity for 9.7 percent more input, and the printed coefficient drops from 3.92 to 3.88. If the load genuinely needs it, the step is justified; as margin alone it is a net loss on efficiency.
Is there a page for KSN78V11VDZ on the supplier site?
No. A site index scan returns nothing for KSN78, and the two natural candidate URLs both return 404. The edition is the only public document for this string.
What is missing from the row?
Mass, oil grade and charge, running current, speed, sound level, locked-rotor current and ingress protection are all absent. Voltage and frequency are printed at block level only, and no heating rating appears at all.
Sources
| Reference | Use in this article | Link |
|---|---|---|
| GMCC rotary compressor catalogue, 2024 edition, 20 pages, 2,990,900 bytes, MD5 5c58f3bf5681501f481fd8396febc207 | Row, ladder, block header, naming rule, four 7.8 builds | PDF mirror, enstar-hvac |
| GMCC product centre | Current range listing | gmcc-welling.com product page |
| GMCC download list | Official route to the catalogue file | gmcc-welling.com download list |
| IEC 60335-2-34 | Motor-compressor safety standard | webstore.iec.ch |
| Regulation (EU) 2024/573 | Fluorinated gas framework | eur-lex.europa.eu |
| IEA, The Future of Cooling | Cooling demand context | iea.org report |
| Site pages for fixed-speed and inverter neighbours | Voltage field pattern, displacement defects | qishanrcompressor.com |