KSG165V1UMT GMCC Rotary Air Conditioner Compressor
GMCC KSG165V1UMT Rotary Air Conditioner Compressor: The 2024 Catalogue Row, the ARI Condition, and a Shop Page That Names R404A
| Field | What the 2024 catalogue prints | Where it comes from |
|---|---|---|
| Model string | KSG165V1UMT | printed page 14, one row only |
| Family and series | SG, inside the green refrigerant air-conditioning section | series label printed beside the rows |
| Refrigerant | R32 | block header on the same page |
| Supply | 1ph, 50 Hz, 220/240 V | block header on the same page |
| Test condition | ARI | block header on the same page |
| Displacement | 16.7 cm3/rev | row |
| Cooling capacity | 4285 W, printed also as 14620 Btu/h | row |
| Power input | 1440 W | row |
| COP | 2.98 | row |
| Run capacitor | 40/400 | row |
| Height | 310 mm | row |
| Development status | in production, no development mark | row carries no triangle |
Three things follow from that page, and they are the spine of everything below. First, the printed coefficient is an ARI-condition coefficient, and the same catalogue prints the same family under GX and ASH on the pages either side of it, where the coefficient is up to 45 per cent higher on hardware of the same displacement. Second, the three-digit code 165 is a nominal class rather than a measured displacement: two builds share the code and print 16.7 and 16.5 cm3/rev. Third, one of the two shop pages says R404A for this string, which the catalogue, the model letter and the other shop page all contradict.
Is KSG165V1UMT in the 2024 catalogue?
Yes. The string appears exactly once in the twenty-page document, on what the catalogue numbers page 14, in the section headed GREEN REFRIGERANT COMPRESSOR.
Two production details are worth knowing before reading the row, because they explain most of the confusion around this family. The file is laid out as spreads: each PDF page carries two printed pages, and the folio numbers for both halves sit side by side at the foot. So a search that reports a hit on the ninth page of the file is reporting a hit on printed pages 13 and 14, and only the horizontal position of the row tells you which half it belongs to. KSG165V1UMT sits in the right half, at the model column that begins around x=699 on that spread, which is why it is printed page 14.
The second detail is that each half page is an independent table with its own header band. The band above this row prints R 32, then 1ph, 50 Hz, 220/240 V, then the test condition ARI, and a series column that runs SN, SM, SF, SG, TQ down the side. The row belongs to the SG group, the third of the three SG rows on that half page.
The model is in production. The catalogue marks rows still under development with a filled triangle in the last column and prints the legend that products carrying the mark are under development. The KSG165V1UMT row carries no such mark, and neither do the two SG rows beside it; the triangle appears on the row above, on KSF210V1UFPB3, which is how you can tell the mark is genuinely per-row and not decoration.
The wider KSG family is spread over four printed pages, not one. Twenty rows carry a KSG string: three on page 13, three on page 14, ten on page 15 and four on page 17. Only one of those twenty is this model. Anyone comparing KSG numbers found by search needs to check which of the four pages each one came from, because the header band, and therefore the refrigerant, the supply and the test condition, changes between them.
The row as the catalogue prints it
The row prints nine values after the model string, all of them at the ARI condition the block header names. Only three of the column headings survive in the text layer of this block: the typical model, the cooling capacity, and the displacement. The rest are set as graphics, and the words that would head the diameter columns do not occur anywhere in the document's text, so the field names below follow the column order of the block and the units the values themselves carry.
| Position | Printed value | Field |
|---|---|---|
| 1 | 16.7 | displacement, cm3/rev |
| 2 | 4285 | cooling capacity, W |
| 3 | 14620 | cooling capacity, Btu/h |
| 4 | 1440 | power input, W |
| 5 | 2.98 | COP, W/W |
| 6 | 40/400 | run capacitor, microfarad and volt-AC |
| 7 | 310 | compressor height, mm |
| 8 | 9.8 | pipe diameter, mm; column heading is graphic in this block |
| 9 | 16.2 | pipe diameter, mm; column heading is graphic in this block |
The five arithmetic fields close against each other, which is the cheapest test of whether a row has been transcribed correctly:
4285 divided by 1440 gives 2.9757, printed as 2.98. 4285 multiplied by 3.412 gives 14620.4, printed as 14620. The swept volume is 16.7 multiplied by 60, or 1002 cm3 per second, so the row consumes 1440 divided by 1002, or 1.4371 W for every cm3 per second swept. Capacity per swept cm3 is 4285 divided by 16.7, or 256.6 W.
Those last two figures are the ones to keep, because they are the only way to compare rows that are printed at different displacements. A capacity in watts says nothing on its own; watts per swept cm3 says how hard the machine is being run, and watts per swept cm3 per second says how much electricity that costs.
Reading the string: K, S, V and the three digits
The catalogue prints its naming rules on page 5, and four of the characters in this string can be checked against that page and then against the printed block header, which is a much stronger test than reading the rule table alone.
| Character | Naming rule says | Checked against |
|---|---|---|
| K | refrigerant code for R32 and R410A | block header prints R 32 |
| SG | series name | series label printed beside the row |
| 165 | displacement code, cm3/rev multiplied by 10 | row prints 16.7, and the other build prints 16.5 |
| V | single phase, 50 Hz, 220/230/240 V | block header prints 1ph, 50 Hz, 220/240 V |
| 1, U, M, T | motor specification, structure change, conditions of use, accumulator and base codes | not decoded in this article |
The power-code check is worth spelling out because it is the one that makes the rest of the family readable. The naming page lists twelve power codes in order and twelve supply descriptions in order, and the identical ordering works on four separate printed blocks: V gives 50 Hz single phase at 220/240 V, which is what the KSG165V1UMT block prints; S gives 50 Hz single phase at 230 V, which is what the block holding KSG165S1VMT and KSG210S1VMP prints; N gives 60 Hz single phase at 208 to 230 V, which is what the block holding KSG230N1VMT prints. Three independent headers, three correct predictions. That is enough to trust the mapping for this family, and it is also enough to spot a mislabelled supply at a glance.
The duty field is the one that answers the description in the request. The naming page lists an application field whose default entry is compressors for air conditioning, with separate markers for heat pump, freezing and cold storage, heating, and cabinet air conditioning. KSG165V1UMT carries none of those four duty markers, and it is printed inside the section headed, in the original, green refrigerant air-conditioning compressor. So the phrase rotary air conditioner compressor is documented twice over: once by the section the row sits in and once by the default entry of the duty field. It is not a description added by a shop, which is worth saying because for some GMCC strings the shop wording and the catalogue disagree.
The letter-K rule can also be checked against a worked example rather than against the rule table alone, and the blog side of the site carries an R410A compressor in the same letter family. That is the clearest demonstration that the letter names a refrigerant class and not a single gas.
What is not decoded here is the run of characters after the power letter. The naming page lists positions for motor specification, structure change, conditions of use, and accumulator and base geometry, and a reader can see that KSG165V1UMT and KSG165S1VMT differ in exactly one of those positions, the power letter, since S and V are both single-phase 50 Hz codes. Nothing later in this article depends on decoding the rest, and no figure is inferred from them.
Two builds share the 165 code, and they print different numbers
This is the first place where a buyer can go wrong, and it is worth a table because the two rows look interchangeable until you put them side by side.
| Field | KSG165V1UMT | KSG165S1VMT | Difference |
|---|---|---|---|
| Printed page | 14 | 15 | different block |
| Supply code | V, 220/240 V | S, 230 V | different supply |
| Test condition | ARI | GX | see next section |
| Displacement | 16.7 cm3/rev | 16.5 cm3/rev | minus 0.2 |
| Cooling capacity | 4285 W | 5185 W | plus 21.0 per cent |
| Power input | 1440 W | 1200 W | minus 16.7 per cent |
| COP | 2.98 | 4.32 | plus 45.0 per cent |
| Capacity per swept cm3 | 256.6 W | 314.2 W | plus 22.4 per cent |
| Capacitor | 40/400 | 40/400 | same |
| Height | 310 mm | 310 mm | same |
Two rows, one nominal class, and a gap of 21 per cent in capacity and 45 per cent in coefficient. The capacitor and the height are identical, which means the two builds are physically close; the supply code differs by one letter. Nobody should carry a number across that table, and nobody should assume that a quotation quoting 5185 W is quoting this model.
The displacement line is the quieter finding. The code is 165 for both, and the printed displacement is 16.7 for one and 16.5 for the other. Across the twenty KSG rows in the document, the printed displacement sits within 0.2 cm3/rev of the code divided by ten, sometimes above and sometimes below, and it is exactly equal on nine of them. The three digits are therefore a nominal class, not a measurement, and dividing capacity by the code is not a valid normalization. That is why the table above uses capacity per swept cm3 computed from the printed displacement rather than from the code.
What the ARI condition does to the printed coefficient
The condition is not a footnote. The catalogue marks every block with a condition code, and the same family is printed under several of them on consecutive pages. The legend page, printed 34, distinguishes a nominal-power-supply basis from a basis it labels as being for higher efficiency products, and adds separate entries for forced air cooling, a North American dehumidifier condition and a North American unitary condition. What the legend does not do, anywhere in the text layer of the document, is print a numeric definition of the ARI condition: the code appears on every block that uses it, and no table of evaporating and condensing points accompanies it.
The cleanest way to see the size of the effect is to hold the hardware still. There are three rows in this family that all print 22.9 cm3/rev, all single phase, all in the same SG series.
| Field | KSG230V1UKU | KSG230S1VMU | KSG230N1VMT |
|---|---|---|---|
| Supply | 1ph, 50 Hz, 220/240 V | 1ph, 50 Hz, 230 V | 1ph, 60 Hz, 208 to 230 V |
| Test condition | ARI | GX | GX |
| Displacement | 22.9 cm3/rev | 22.9 cm3/rev | 22.9 cm3/rev |
| Cooling capacity | 5945 W | 7110 W | 8525 W |
| Power input | 1980 W | 1655 W | 1930 W |
| COP | 3.00 | 4.30 | 4.42 |
| Capacity per swept cm3 | 259.6 W | 310.5 W | 372.3 W |
Reading across the first two columns isolates the condition, because the displacement is identical and both rows are 50 Hz single phase: capacity rises 19.6 per cent, power falls 16.4 per cent, and the printed coefficient rises 43.3 per cent. Reading across the second and third columns isolates frequency instead, because both are GX: capacity rises 19.9 per cent, power rises 16.6 per cent, and the coefficient moves only 2.8 per cent. That is the shape of the trap. A frequency change lifts capacity and power together and leaves efficiency almost alone; a condition change moves efficiency by more than forty per cent without touching the hardware.
The same pattern holds for the 165 code. The ARI row prints 256.6 W per swept cm3 and the GX row prints 314.2. The two ASH rows in the family, KSG240V1SMV and KSG180V1SFT, print 257.9 and 250.0, which is close to the ARI level and far from the GX level. Any comparison that mixes an ASH or ARI number with a GX number is comparing test benches, not compressors.
For a buyer the practical consequence is simple. If the design point is a GX-style rating, this row cannot supply that figure; the GX rows at 16.5 cm3/rev and above exist and can. If the design point is the ARI basis, use the row as printed and do not inflate it by borrowing from the page next door.
The SG block on the same page: three rows and a straight ladder
The SG group on page 14 has three rows, all three printed at the ARI condition, and in this block the ladder is unusually well behaved. Capacity per swept cm3 barely moves across it, which means the catalogue is scaling a single design rather than switching architecture between sizes.
| Model | Displacement | Capacity | Power | COP | W per cm3 | W per cm3/s |
|---|---|---|---|---|---|---|
| KSG165V1UMT | 16.7 cm3/rev | 4285 W | 1440 W | 2.98 | 256.6 | 1.4371 |
| KSG185V1UKU | 18.5 cm3/rev | 4775 W | 1605 W | 2.98 | 258.1 | 1.4459 |
| KSG230V1UKU | 22.9 cm3/rev | 5945 W | 1980 W | 3.00 | 259.6 | 1.4410 |
Specific capacity runs 256.6, 258.1 and 259.6, a spread of 1.2 per cent across a 37 per cent displacement range. Specific power runs 1.4371, 1.4459 and 1.4410, a spread of 0.6 per cent. This is what a linear ladder looks like in printed data, and it has a commercial consequence: stepping up from 16.7 to 18.5 cm3/rev buys 11.4 per cent more capacity for 11.5 per cent more power at the same coefficient, and stepping from 18.5 to 22.9 buys 24.5 per cent more capacity for 23.4 per cent more power with the coefficient improving by two hundredths. There is no efficiency penalty for taking the larger frame inside this block, and conversely no efficiency reward for downsizing and running the smaller frame harder than its rating.
The three rows also differ in the capacitor: 40/400 for the two smaller rows, 45/400 for the 22.9. That is a starter-component difference a panel builder has to know about before ordering, and it is the kind of field that a shop summary usually drops.
Where the shop pages disagree with the catalogue
Two shop domains carry this family, and they do not say the same thing. The most consequential difference is the refrigerant.
| Source | Model | Refrigerant named | Capacity printed | Power printed | COP printed |
|---|---|---|---|---|---|
| 2024 catalogue, page 14 | KSG165V1UMT | R32 | 4285 W | 1440 W | 2.98 |
| qishanr.com model page | KSG165V1UMT | R404A | not printed | not printed | not printed |
| qishanrcompressor.com, page for KSG230V1UKU | KSG230V1UKU | R32 | 7765 W | 1654 W | 4.42 |
| 2024 catalogue, page 14 | KSG230V1UKU | R32 | 5945 W | 1980 W | 3.00 |
| qishanrcompressor.com, page for KSG210S1VMP | KSG210S1VMP | R32 | 6610 W | 1495 W | 4.42 |
| 2024 catalogue, page 15 | KSG210S1VMP | R32 | 6610 W | 1495 W | 4.42 |
| qishanrcompressor.com, page for KSG280V1VMU | KSG280V1VMU | R32 | 8630 W | 2045 W | 4.22 |
| 2024 catalogue, page 13 | KSG280V1VMU | R32 | 8620 W | 2060 W | 4.18 |
On the refrigerant, the catalogue wins on three counts and the qishanr.com field loses on all three. The block header on page 14 prints R 32. The model letter K is the code for R32 and R410A, while R404A has its own letter, S, in the same naming table. And the second shop domain prints R32 for every KSG page it carries. The R404A field is not an isolated data-entry slip either: the same field, with the same wording, appears on the model pages for KSG230V1UKU, KSG280V1VMU and KSG210S1VMP, so it is a template value applied to the whole family rather than a per-model error. Treat it as a page defect and take the catalogue value, but do not be surprised when a customer quotes it back at you, because it is what the site prints.
The capacity differences are a separate matter. The page for KSG210S1VMP reproduces its row exactly, to the watt, and closes internally: 6610 divided by 1495 gives 4.4214, printed as 4.42. The page for KSG280V1VMU closes internally too, at 8630 divided by 2045, or 4.2200 against a printed 4.22, but every one of its four figures sits slightly away from the catalogue row: capacity 0.1 per cent higher, power 0.7 per cent lower, coefficient up by four hundredths. That is the signature of a page rebuilt from a different revision rather than a misprint, and it is small enough that a quotation copied from it would look right and be wrong at the margin.
The page for KSG230V1UKU is the one that needs care. It prints 7765 W against 1654 W, which divides to 4.6947, but the page prints COP 4.42. The page does not close against itself. Its power figure sits within one watt of the GX row at the same displacement, 1655 W, while its capacity sits 30.6 per cent above the ARI row, 9.2 per cent above the GX row and 8.9 per cent below the 60 Hz GX row. Its coefficient, 4.42, is exactly the coefficient of the 60 Hz row. Three fields, three different sources, one table. That is not a parameter set; it is a composite.
Two smaller defects are worth recording because they affect how the pages can be cited. The page for KSG210S1VMP heads itself with the word Inverter, while the block it reproduces is a fixed-speed 230 V block with a run capacitor printed, and the naming page's inverter codes are a separate family from the S code this row carries. And the qishanrcompressor.com domain, at the time of writing, serves a blank application shell to clients that do not execute JavaScript, so its pages have to be read through a rendering fetcher; the content quoted above was read that way, and the same request without rendering returns an empty page with a blank title.
How to write the purchase order
The catalogue gives enough to specify the part and not enough to specify its performance at an arbitrary design point. The purchase order should carry both halves of that.
Pin the identity first. The full string is KSG165V1UMT, it is the SG series, and it is the only row with that string in the 2024 catalogue, printed on page 14. A quotation that names only 165 is ambiguous, because the 165 code is shared with KSG165S1VMT on the next page and the two are not interchangeable.
Before fixing the frame size, it is worth reading the family as a range rather than as one row. The GMCC rotary compressor range page on the site indexes the sibling codes with their published figures, and the wider rotary compressor category sets this series beside the other rotary families. A buyer who needs a scroll frame instead should start from the GMCC scroll line, which the same catalogue covers under its own condition codes.
Pin the supply second, because it decides the capacity. The row is single phase, 50 Hz, 220/240 V. The 230 V single-phase code and the 60 Hz code both occur in this family and both change the numbers substantially, so a purchase order that leaves the supply open leaves the capacity open by around twenty per cent.
Pin the condition third, and write it into the document. The performance figures 4285 W, 1440 W and 2.98 belong to the ARI condition and to nothing else. If the design point is a different basis, ask for the row that carries that basis, or ask for a rating at the design point in writing.
Then state what the catalogue does not. It prints no numeric definition of the ARI condition, no safety classification and no global warming potential for the refrigerant; the words that would carry those values do not appear anywhere in the twenty-page document. It prints no sound level, no oil charge and no connection sizes with legible headings for this block. Those four items have to come from a specification sheet, not from the catalogue.
Finally, ask for the refrigerant in writing. Given that one of the two shop domains prints R404A against this string, a purchase order that says only the model number is inviting exactly the ambiguity the page creates. The catalogue says R32, the model letter says R32, and the second shop domain says R32; the order should say R32 and should require the supplier to confirm it.
Standards and approvals that frame the purchase
A hermetic rotary compressor for air conditioning sits under two parts of the same household appliance series, and they answer different questions.
The component question is answered by IEC 60335-2-34, the part written for motor-compressors, which covers the compressor as a component. The appliance question is answered by IEC 60335-2-40, the part written for electrical heat pumps, air conditioners and dehumidifiers, whose scope states that it does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817, and which relies on the first standard for its definition of a motor-compressor. For a buyer assembling a unit rather than reselling a part, the second is the standard the finished product is tested against, and its refrigerant grouping is the reason the safety file has to name the fluid rather than the model.
The refrigerant itself is designated by ANSI/ASHRAE Standard 34. Its published designation tables name R-32 as difluoromethane, a single-compound refrigerant, and list both R-410A and R-454B as blends with R-32 as a component, at 50.0/50.0 with R-125 and at 68.9/31.1 with R-1234yf respectively. That matters for this row in a specific way: R404A, the fluid printed on one of the shop pages, is a blend of R-125, R-143a and R-134a, and shares no component with R32. A single-compound fluid and a three-component blend are not alternative labels for the same gas. The two parts of the safety series, and the refrigerant standard that supplies their group letters, are listed together on the ASHRAE standards and guidelines page.
The commercial case for caring about the coefficient at all is set out in two public studies. The IEA's work on cooling records that air conditioners and electric fans already account for nearly 20 per cent of the electricity used in buildings worldwide, that energy demand for space cooling will more than triple by 2050 without action on efficiency, and that the average efficiency of units sold today is less than half of what is typically available on the shelf. The Climate and Clean Air Coalition's compilation of stationary air conditioning case studies makes the same point from the refrigerant side, describing stationary air conditioning as the largest and most rapidly growing area of HFC use. Neither document says anything about this model, and neither is a substitute for its rating; they explain why a 45 per cent spread in printed coefficient, produced by a change of test bench rather than a change of hardware, is worth pinning down before an order.
The primary documents behind the row are published by the manufacturer rather than by a reseller: the product centre indexes the current series, and the downloads page carries the catalogues and technical material from which the 2024 edition is taken.
Frequently asked questions
Does the 2024 catalogue print KSG165V1UMT?
Yes, once. It is on printed page 14, in the right half of the PDF spread that carries folios 13 and 14, in the green refrigerant air-conditioning section. The row is KSG165V1UMT, 16.7, 4285, 14620, 1440, 2.98, 40/400, 310, 9.8, 16.2, and it carries no development mark.
What refrigerant does the row use?
R32. The block header on the same page prints R 32, the model letter K is the naming code for R32 and R410A, and the second shop domain prints R32 on every KSG page it carries.
Why does one shop page say R404A?
Because that field is a template value on that domain, not a per-model reading. The same R404A line appears on the pages for KSG165V1UMT, KSG230V1UKU, KSG280V1VMU and KSG210S1VMP, against a catalogue that prints R32 for every one of those rows and against a naming table in which R404A has its own letter. Treat it as a defect, cite the catalogue, and confirm the fluid in writing on the order.
What does the ARI condition mean here?
It is the code the catalogue prints in the block header to identify the test bench behind the capacity, power and coefficient figures. The catalogue's legend page distinguishes a nominal-power-supply basis from a higher-efficiency basis and separates several special conditions, but it prints no numeric definition of ARI in its text layer, so the code identifies the bench without letting a reader reproduce it. What can be measured is the size of the effect: holding displacement and supply fixed and changing only the condition, the printed coefficient moves 43.3 per cent.
Can I use the KSG165S1VMT figures instead?
No. That row is 16.5 cm3/rev on a 230 V supply at the GX condition, and it prints 5185 W, 1200 W and 4.32 against this row's 4285 W, 1440 W and 2.98. The two share a nominal class and nothing else that matters.
What is the capacity in tons?
The row prints 4285 W and 14620 Btu/h. Converting Btu/h to tons at 12000 Btu/h per ton gives 1.22, which is arithmetic on a printed figure and not a rating the catalogue states. Quote the printed units in a specification and keep the conversion, if you need it, in a covering note.
Is it fixed speed or inverter?
Fixed speed, as printed. The block carries no inverter designator, the row prints a run capacitor value of 40/400 where the catalogue's inverter blocks print a dash in that column, and the naming page lists inverter supplies as separate codes from the V code this row carries. The catalogue also separates its inverter blocks under their own section heading.
Which page should I cite to a customer?
The catalogue, page 14, for every electrical and performance figure, and the model page on the second shop domain for availability and packaging. Do not cite the R404A field, and do not cite the 7765 W figure printed on the KSG230V1UKU page, which does not close against its own power figure.
Where can I check the row myself?
Open the 2024 catalogue and go to printed page 14, right half. The block header prints R 32, then the supply, then the ARI condition, and the SG group is the second group from the bottom of that table, with the TQ group below it. The row is the first of the three SG rows. If you are comparing against a search result rather than a page image, remember that the file packs two printed pages per PDF page, so the folio at the foot of the half you are reading is the page number to cite. Release notes for the site's own model pages are collected in the news index.
Sources
| Source | Document | Use in this article |
|---|---|---|
| S460 | GMCC Rotary Compressor Product Catalog, 2024 edition, 20 pages, 2990900 bytes, md5 5c58f3bf5681501f481fd8396febc207 | the KSG165V1UMT row on printed page 14, the block header, the three SG rows, the 22.9 comparison rows, the KSG census, the development mark, the section titles |
| S461 | Same catalogue, naming rules page, printed 5 | refrigerant letters, duty field and its default, displacement code, the twelve power codes and their supplies |
| S462 | Same catalogue, legend page, printed 34 | the condition legend, and the absence of a numeric definition of the ARI condition |
| S463 | qishanrcompressor.com model pages for KSG230V1UKU, KSG210S1VMP and KSG280V1VMU | the shop-side capacity, power and coefficient figures, the inverter heading on the KSG210S1VMP page, the template usage line |
| S464 | qishanr.com model pages for KSG165V1UMT, KSG230V1UKU, KSG280V1VMU and KSG210S1VMP | the R404A field and its repetition across four pages, the supply and application lines |
| S465 | IEC 60335-2-34:2024 and IEC 60335-2-40:2024, IEC webstore | the component and appliance safety scope, the refrigerant grouping clause and the motor-compressor definition |
| S466 | ANSI/ASHRAE Standard 34 designation tables, ASHRAE | the designation of R-32, R-404A, R-410A and R-454B |
| S467 | IEA, The Future of Cooling; Climate and Clean Air Coalition, Lower-GWP Alternatives in Stationary Air Conditioning | the building electricity share, the space cooling demand outlook and the HFC growth framing |